Samsung iPolis SND-460V User Manual page 9

1/3" high performance network dome camera
Hide thumbs Also See for iPolis SND-460V:
Table of Contents

Advertisement

Ch3. Installation and Network Setup
■ Connecting Alarm Input
This is the input terminal for external alarm signal, use it by connecting as following.
3.3V
120
5.1K
Ω
Ω
Sensor Input
10K
Ω
• In case of selecting Normal Open at setup menu :
In case of contact type, it is short and in case of active type, sensor input acts at "LOW" level.
• In case of selecting Normal Close at setup menu :
In case of contact type, it is open and in case of active type, sensor input acts at high
impedance status(open collector).
16
NETWORK CAMERA
Camera
Internal
Alarm In
Sensor
GND
User's Manual
■ Connecting Alarm output
This is the output terminal for external alarm signal, use it by connecting as following.
Open Collector
2.2K
Ω
CMOS Output
10K
Ω
• Alarm output part is Open Collector structure and can be composed by using relay. Rated
maximum value is DC +24V, 100 mA.
NETWORK CAMERA
Alarm Out
Relay
Relay
Output
Relay
Power
GND
17
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents