Panasonic AWHE60H Operating Instructions Manual page 28

Hd integrated camera
Table of Contents

Advertisement

Black level (master pedestal) adjustment
When performing the operations using the controller
When the AW‑RP655 is connected:
1
Press the [IRIS] button several times to turn off
its lamp.
Set the iris to the manual ([MANU]) mode.
2
Turn the [FOCUS/IRIS] dial to stop down the
lens iris.
3
Press the [R/B GAIN/PED] button several
times so that the "PEDESTAL TOTAL" item is
displayed on the LCD panel.
4
Turn the jog dial (main) and adjust the black
level to 0.035 V.
5
If necessary, adjust the iris automatically.
 Press the [IRIS] button several times to turn on its
lamp.
28
(continued)
When the AW‑RP555 is connected:
1
Press the [IRIS] button several times to turn off
its lamp.
Set the iris to the manual ([MANU]) mode.
2
Turn the [LEVEL] dial of [IRIS] to stop down the
lens iris.
3
Follow the operation steps in "Basic
operations" (page 38), and use the camera menu
to perform the adjustment.
When the AW‑RP50 is connected:
Refer to the Operating Instructions of the controller.