Alto-Shaam COMBITOUCH SERIES 6•10ESG Installation Manual
Alto-Shaam COMBITOUCH SERIES 6•10ESG Installation Manual

Alto-Shaam COMBITOUCH SERIES 6•10ESG Installation Manual

Combination oven / steamer es gas combitouch series
Hide thumbs Also See for COMBITOUCH SERIES 6•10ESG:

Advertisement

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744
PRINTED IN U.S.A.
C o m b i t h e r m
C o m b i n a t i o n
O v e n / S t e a m e r
C O M B I TO U C H ™
• I N STA LLAT I O N
USA/CANADA
WWW.ALTO-SHAAM.COM
E S GAS
S E R I E S
6• 10
10 •10
7• 14
10 •20
12 •18
20 •20
FAX: 262.251.7067 • 800.329.8744
®
G
E S
G
E S
G
E S
G
E S
G
E S
G
E S
U.S.A. ONLY
MN-29246 • 10/10

Advertisement

Table of Contents
loading

Summary of Contents for Alto-Shaam COMBITOUCH SERIES 6•10ESG

  • Page 1 • I N STA LLAT I O N W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 FAX: 262.251.7067 • 800.329.8744 USA/CANADA U.S.A. ONLY WWW.ALTO-SHAAM.COM PRINTED IN U.S.A. MN-29246 • 10/10...
  • Page 2: Table Of Contents

    Delivery ................1 Electrical Connection ..........13 Unpacking ..............1 Mobile Equipment Restraint ........14 Safety Procedures and Precautions ......2 Ventilation Requirements ......... 15 Gas Supply & Installation ......... 16 Installation Gas Leak Testing ............19 Installation Codes and Standards ......3 Gas Exhaust .............
  • Page 3: Delivery

    Additional model. Contact the Alto-Shaam Tech Team Service manuals are available from the Alto-Shaam Department if you have any questions concerning Tech Team Service Department.
  • Page 4: Safety Procedures And Precautions

    SAFETY PROCEDURES AND PRECAUTIONS Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold safe operation of electrically and/or gas energized or process foods for the purpose of human equipment. In accordance with generally accepted consumption.
  • Page 5: Installation

    INSTALLATION SITE INSTALLATION D A N G E R D A N G E R IMPROPER INSTALLATION, AVERTISSEMENT : UNE INSTALLATION, ALTERATION, ADJUSTMENT, UN AJUSTEMENT, UNE ALTÉRATION, SERVICE, OR MAINTENANCE COULD UN SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER RESULT IN SEVERE INJURY, DEATH, DES DOMMAGES À...
  • Page 6: Positioning On Site

    INSTALLATION SITE INSTALLATION POSITIONING ON SITE Lift the oven from the pallet with a fork lift or pallet lift truck positioned at the front of the oven. For damage protection, the use of two wooden boards, placed between the bottom of the oven and the lifting forks, is strongly recommended.
  • Page 7: Positioning Requirements

    INSTALLATION SITE INSTALLATION POSITIONING REQUIREMENTS q In order to ensure proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the control panels side (left) of the oven and any adjoining surfaces. NOTE: Additional clearance is needed for service access.
  • Page 8: Common Specifications

    (CITRUS BASED, NON-CORROSIVE DELIMING PRODUCT) CASE = FOUR 4-LB BOTTLES; 4-LB BOTTLE MAKES 10 GALLONS q Service Start-Up Check SPECIFY AS REQUIRED AVAILABLE THROUGH AN ALTO-SHAAM FASTEAM CENTER Grilling Grate SH-26731 COMBITOUCH ESG SERIES • GAS INSTALLATION MANUAL • 6.
  • Page 9: Specifications, 6•10Esg

    17-3/4” x 17-3/8” x 26-13/16” (450mm x 440mm x 680mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM TWO (2) COLD WATER INLETS - DRINKING QUALITY * Can manifold off of WATER QUALITY STANDARDS WILL VOID THIS WARRANTY.
  • Page 10: Specifications, 10•10Esg

    27-3/8” x 17-3/8” x 26-13/16” (695mm x 440mm x 680mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD WATER INLETS - DRINKING QUALITY USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. 3/4” NPT* * Can manifold off of ONE (1) TREATED WATER INLET: one 3/4”...
  • Page 11: Specifications, 7•14Esg

    23-5/8” x 25-1/4” x 33-7/8” (600mm x 640mm x 860mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD WATER INLETS - DRINKING QUALITY USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. * Can manifold off of ONE (1) TREATED WATER INLET: 3/4”...
  • Page 12: Specifications, 10•20Esg

    33-7/8” x 25-1/4” x 33-7/8” (860mm x 640mm x 860mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD WATER INLETS - DRINKING QUALITY USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. 3/4” NPT* ONE (1) TREATED WATER INLET: * Can manifold off of one 3/4”...
  • Page 13: Specifications, 12•18Esg

    33-7/8” x 25-1/4” x 33-7/8” (860mm x 640mm x 860mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD WATER INLETS - DRINKING QUALITY USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. 3/4” NPT* * Can manifold off of ONE (1) TREATED WATER INLET: one 3/4”...
  • Page 14: Specifications, 20•20Esg

    54-15/16” x 25-1/4” x 33-7/8” (1395mm x 640mm x 860mm) WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD WATER INLETS - DRINKING QUALITY USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. 3/4” NPT* ONE (1) TREATED WATER INLET: * Can manifold off of one 3/4”...
  • Page 15: Electrical Connection

    INSTALLATION ELECTRICAL D A N G E R MODEL VOLTAGE PHASE CIRCUIT 6•10esG AND 110-120 20 A 2 WIRE 6•10esG/SK ELECTRICAL GROUNDING 7•14esG AND 110-120 20 A 2 WIRE INSTRUCTIONS: 7•14esG/SK This appliance is equipped with a 10•10esG AND 110-120 20 A 2 WIRE three-pronged (grounding) plug for...
  • Page 16: Mobile Equipment Restraint

    INSTALLATION MOBILE EQUIPMENT RESTRAINT The gas Combitherm must use a connector that Install a manual gas shut-off valve along with an complies with The Standard for Connectors for approved disconnect device. Movable Gas Appliances, ANSI Z21.69 CSA 6.16 and . Install an A.G.A. certified, heavy-duty connector addenda Z21.69a-1989.
  • Page 17: Ventilation Requirements

    INSTALLATION VENTILATION REQUIREMENTS D A N G E R An adequate ventilation system is required for commercial cooking equipment. Information may be Installation, air adjustment and/or obtained by writing to the National Fire Protection service work must be in accordance Association, Batterymarch Park, Quincy, MA 02269.
  • Page 18: Gas Supply & Installation

    INSTALLATION GAS SUPPLY & INSTALLATION The Alto-Shaam gas Combitherm has been set D A N G E R to operate with either natural gas or propane as indicated on the identification name plate. Make certain the gas supply matches the nameplate CONNECTING TO THE WRONG GAS information.
  • Page 19 INSTALLATION GAS SUPPLY & INSTALLATION D A N G E R D A N G E R Installation, air adjustment and/or DO NOT store or use gasoline or other service work must be in accordance fl ammable vapors or liquids in the with all local codes and must be vicinity of this or any other appliance.
  • Page 20 INSTALLATION GAS SUPPLY & INSTALLATION The other end of the cable should be permanently The minimum size requirement for gas piping or a attached to the rear frame of the oven. The cable flexible connector is 3/4 - inch (19mm). For long runs should be of sufficient length so that no strain is ever of gas piping, the pipe diameter must conform to the placed on the flexible gas connector in the event of...
  • Page 21: Gas Leak Testing

    INSTALLATION GAS SUPPLY & INSTALLATION LEAK TESTING If a pressure leak test above 1/ 2 psi is to be The use of an electronic combustible gas leak performed on the building supply gas piping, the detector is helpful, however, this type of detector shut-off gas valve and oven inlet gas supply line can be oversensitive.
  • Page 22: Water Quality Requirements

    Alto-Shaam Combitherm warranty. producing equipment. Since water quality is an important issue, Alto-Shaam is committed to provide Alto-Shaam will continue our efforts to provide as much information as possible to help protect the viable solutions to ease the impact of water quality as investment made in this equipment.
  • Page 23: Water Supply & Installation

    FI-23014 shown BOTH TREATED AND UNTREATED WATER CONNECTIONS MUST BE CONNECTED FOR PROPER OPERATION OF THE OVEN. Alto-Shaam now offers an improved water filtration BOTH CONNECTIONS CAN BE system for Combitherm . The CombiGuard™ 10 & ® TREATED WATER, BUT SHOULD...
  • Page 24: Water Valve

    INSTALLATION WATER VALVE SHUT-OFF VALVE SHOWN IN THE OFF POSITION NOTE: THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION WHEN THE OVEN IS BEING USED. WATER DRAINAGE The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied with a 1-1/2-inch (41mm) NPT thread.
  • Page 25: Combitouch Checklist

    10’ (305cm) of drain line. STORE HAS SEEN THIS RECOMMENDATION: IMPORTANT: Alto-Shaam has listed Water Quality Requirements in the installation manual for this equipment. It is the responsibility of the end user to have the water connected to this appliance tested SIGNATURE OF STORE REPRESENTATIVE: to ensure these standards are met before putting the oven into use.
  • Page 26: Error Codes

    ☛ Check the power flow to the unit. Plug in outlet? Do not attempt to repair or service the CombiOven beyond this point. Contact Alto-Shaam for the nearest authorized service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam will void the warranty on the unit.
  • Page 27 INSTALLATION CombiTouch ERROR CODES Error Error call out in Display Description of Error Possible reason Code Boiler Temperature High Boiler temperature overheats — Scale build up inside steam generator. — Scale build up on water level probe. — B4 Probe connection problem. —...
  • Page 28 INSTALLATION CombiTouch ERROR CODES Error Error call out in Display Description of Error Possible reason Code Steam Generator Drain Water level in steam — Scale build up inside the steam generator drain Pump Fault generator does not drop pump. during cleaning program —...
  • Page 29 INSTALLATION CombiTouch ERROR CODES Error Error call out in Display Description of Error Possible reason Code No rinse water During rinse no water fl ow — Water supply is shut off. — Low water pressure. is detected through solenoid — Check wiring to all components mentioned below. valve —...
  • Page 30 INSTALLATION CombiTouch MOTOR CONTROL ERROR CODES Type of Error Indication Release of Error Undervoltage LED fl ashing sequence, with 1 fl ash per period. Voltage of intermediate circuit is less than 250V Overvoltage LED fl ashing sequence, with 2 fl ashes per period. Voltage of intermediate circuit exceeds 445V Excess LED fl...
  • Page 31 INSTALLATION ERROR CODES When the oven malfunctions, an error code will appear in the display. PRESS THE START ICON TO ACKNOWLEDGE THE ERROR. The icons that begin to flash represent operational modes that are still usable. When the oven fault is corrected, the Combitherm will return to normal operation. Model Mode Error...
  • Page 32: Original Equipment Limited Warranty

    PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty or to incur on behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.
  • Page 33: Transportation Damage And Claims

    TRANSPORTATION DAMAGE AND CLAIMS All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee.