Page 1
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 FAX: 262.251.7067 • 800.329.8744 CANADA ONLY www.alto-shaam.com M N - 2 9 5 7 8 • 0 1 / 1 2 p r i n t e d i n u...
Additional model. Contact the Alto-Shaam Tech Team Service manuals are available from the Alto-Shaam Department if you have any questions concerning Tech Team Service Department.
SAFETY PROCEDURES AND PRECAUTIONS Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold safe operation of electrically and/or gas energized or process foods for the purpose of human equipment. In accordance with generally accepted consumption.
I N S T A L L A T I O N S I T E I N S T A L L A T I O N This appliance, complete with unattached items D A N G E R and accessories, may be delivered in one or more packages, Check to insure that all the following items have been received as standard with each unit:...
I N S T A L L A T I O N Options and Accessories Plate Carriers, Chrome Plated 1000-BQ2/96 1000-BQ2/128 1000-BQ2/192 Capacity Capacity Capacity each holds four preplated meals Uncovered “P” Carriers DC-2868 DC-2868 DC-2868 Plate Diameter: Max. 10" (254mm) Min. 7-3/4" (197mm) 24 carriers 32 carriers 48 carriers Vertical rung spacing: 2-5/8" (67mm) 96 preplated meals...
I N S T A L L A T I O N E L E C T R I C A L C O N N E C T I O N D A N G E R D A N G E R ELECTRICAL CONNECTIONS MUST ENSURE POWER SOURCE BE MADE BY A QUALIFIED SERVICE...
O P E R A T I O N O P E R A T I N G I N S T R U C T I O N S 4. Load the cabinet with hot food only. Heat Digital The purpose of the holding cabinet is to maintain Indicator Light Display...
O P E R A T I N G I N S T R U C T I O N S H O L D I N G P R O C E D U R E C. Load the plates in the upper section of the Heat Digital Indicator Light...
O P E R A T I N G I N S T R U C T I O N S General Holding Guideline H O L D I N G T E M P E R A T U R E R A N G E Chefs, cooks and other specialized food service MEAT FAHRENHEIT...
C A R E A N D C L E A N I N G C L E A N I N G A N D P R E V E N T I V E M A I N T E N A N C E PROTECTING STAINLESS STEEL SURFACES CLEANING AGENTS It is important to guard against...
C A R E A N D C L E A N I N G The cleanliness and appearance of this unit will contribute considerably to operating efficiency and savory, appetizing food. Good equipment kept clean works better and lasts longer. 5.
S A N I T A T I O N Food fl avor and aroma are usually so closely related that The most accurate method of measuring safe temperatures it is diffi cult, if not impossible, to separate them. There of both hot and cold foods is by internal product is also an important, inseparable relationship between temperature. A quality thermometer is an effective tool for cleanliness and food fl...
S E R V I C E T H E R M O S T A T A C C U R A C Y The electronic thermostat is a precise instrument and is designed to offer trouble free service. If you suspect the temperature inside the holding compartment does not match the temperature indicated on the digital display, follow the instructions listed below.
S E R V I C E T R O U B L E S H O O T I N G Error Code Description Possible Cause Cavity air sensor reading < 5°F. Verify sensor integrity. E-10 Cavity air sensor shorted See sensor test instructions below.
S E R V I C E SERVICE VIEW - 1000-BQ2/192 Shown DETAIL A Part numbers and drawings are subject to change without notice . 1000-BQ2 & • 15 series operation care manual...
S E R V I C E S E R V I C E P A R T S L I S T MO DE L > 1 0 0 0 - B Q 2 / 9 6 1 0 0 0 -B Q 2 /1 2 8 1 0 0 0 - BQ 2 /1 9 2 I T E M D E SC R I P T ION...
S E R V I C E Cable Heating Replacement Service Kit ..No. 4880 1000-BQ2/96 (125V) requires one (1) kit (129' of cable) 1000-BQ2/192 (125V) requires one (1) kit for one (1) cavity or two (2) kits for both cavities (129' of cable per cavity) Service kit includes: CB-3045 Cable Heating Element .............134 feet CR-3226 Ring Connector ................4 IN-3488 Insulation Corner ..............1 foot BU-3105 Shoulder Bushing ............... 12 BU-3106 Cup Bushing ..................
Page 20
1000-BQ2 & • 18 series operation care manual...
Page 21
1000-BQ2 & • 19 series operation care manual...
Page 22
1000-BQ2 & • 20 series operation care manual...
Page 23
1000-BQ2 & • 21 series operation care manual...
Page 24
1000-BQ2 & • 22 series operation care manual...
Page 25
1000-BQ2 & • 23 series operation care manual...
Page 26
1000-BQ2 & • 24 series operation care manual...
Page 27
1000-BQ2 & • 25 series operation care manual...
Page 28
1000-BQ2 & • 26 series operation care manual...
This warranty is exclusive and is in lieu of all other warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall Alto-Shaam be liable for loss of use, loss of revenue or profit, or loss of product, or for any indirect, special, incidental, or consequential damages.
Need help?
Do you have a question about the 1000-BQ2/96 and is the answer not in the manual?
Questions and answers