Operation Code (Op Code) Table - NEC X461UN - MultiSync - 46" LCD Flat Panel Display Control Manual

External control guide
Hide thumbs Also See for X461UN - MultiSync - 46" LCD Flat Panel Display:
Table of Contents

Advertisement

Appendix
A. Operation Code (OP code) Table
Item
Brightness
Contrast
Sharpness
Black Level
Tint
Color
Color Temperature
Color control
Gamma Selection
Movie
Settings
Picture mode
OP
code
page
00h
00h
00h
00h
00h
02h
00h
00h
02h
Adaptive
02h
Contrast
Noise
02h
Reduction
Film Mode
02h
02h
OP code
Parameter
10h
0: dark
|
100(64h): bright
12h
0: low
|
100(64h): high
8Ch
0: dull
|
82(52h): sharp
92h
0: dark
|
63(3Fh): bright
90h
0: purplish
|
63(3Fh): greenish
1Fh
0: pale
|
63(3Fh): deep
54h
0:2600K
|
74(4Ah):10000K
Red: 9Bh
0:
Yellow: 9Ch
|
Green: 9Dh
50(32h):(center)
Cyan: 9Eh
|
Blue: 9Fh
100(64h):
Magenta: A0h
Saturation:
0: pale
8Ah
|
10(0Ah): deep
68h
Gamma
Table Selection
1: Native Gamma
4: Gamma=2.2
8: Gamma=2.4
7: S Gamma
5: DICOM SIM.
6: Programmable
8Dh
0: None
1: Off
2: Low
3: Middle
4: High
20h
0: Off
|
16(10h) : High
23h
1: Off
2: Auto
1Ah
1: sRGB
3: Hi-Bright
4: Standard
5: Cinema
6: ISF-Day
7: ISF-Night
11: Ambient-1
12: Ambient-2
(35/43)
Remarks
100K/step
sRGB:
PC mode only
Cinema:
A/V mode only
ISF-Day:
ISF-Night:
They need an
adjustment by
ISF.

Advertisement

Table of Contents
loading

Table of Contents