Download Print this page

Agilent Technologies PN 8510-16 Product Note page 2

Controlling test port output power flatness

Advertisement

Introduction
1. In this document, "test port" will refer to the point in the system where the test
device is connected. This may be port 1 or port 2 of any 8510 coaxial-based test
set or the end of a cable or adapter that is attached to the DUT.
2. 8510B network analyzers with revision B.06 or later may also be used to achieve
constant test port power levels. To obtain the latest firmware revision order the
11575F upgrade kit.
3. Any 8360 synthesized sweeper with firmware revision of September 25, 1990 or
earlier must be upgraded. To upgrade your 8360 to the latest firmware revision,
order part number 08360-60167.