Instructions For The Installer; Engineer Technical Data - AEG 84602 G Operating Instructions Manual

Table of Contents

Advertisement

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS Width:
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS Gas:
IGNITION HT SPARK
HEAT INPUT
Rear Left Burner
(semi rapid)
Front Left Burner
(rapid)
Rear Right Burner
(semi rapid)
Front Right Burner
(auxiliary)
APPLIANCE CLASS
APPLIANCE CATEGORY
GAS SUPPLY
12
580 mm.
Depth:
510 mm.
Height:
88 mm.
Weight:
8 Kg.
Width:
550 mm.
Depth:
470 mm.
Thickness:
30 mm.
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
Spark Generator
Ispra Control's BF 50046 - 230-240V 0.6 YA T120
Spark Gap : Fixed
1.9 kW (6483 BTU/HR)
2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
1.9 kW (6483 BTU/HR)
1.0 kW (3412 BTU/HR)
3
II2H3+
Natural gas G20 / 20mbar

Advertisement

Table of Contents
loading

This manual is also suitable for:

85600 g856001 g

Table of Contents