ITI 60-804-04 - Concord LCD/VFD Alphanumeric SuperBus Keypad Installation Instructions Manual page 5

2x20 vfd aplhanumeric touchpad
Table of Contents

Advertisement

Additional Touchpad
1.
Disconnect the panel AC power transformer, backup
battery, and turn off the power switch.
2.
Connect all bus device wiring to the panel (including
the wiring that was disconnected in step one of the first
touchpad installation), but make sure no new touchpads
are connected to their wiring harnesses yet.
3.
Verify that all wiring at the panel and at the added
touchpad wiring harnesses are correct (but do not
connect any touchpads to their wiring harness).
4.
Apply power to the panel (turn on the power switch).
5.
Set the RUN/PROGRAM switch to PROGRAM.
Existing (previously installed) touchpad(s) display
PROGRAM MODE.
Or—The display shows
ENTER CODE
ing), indicating you need to enter the install code. After
entering the install code, existing touchpads display
PROGRAM MODE
.
Note
After entering the install code to get into program
mode, the panel allows you to switch between RUN
and PROGRAM mode for 1 hour without re-entering
the code.
6.
At an existing touchpad, press BYPASS or STATUS
until the display shows
7.
Press COMMAND and the display shows
.
NUMBER
8.
Press COMMAND; existing touchpads will display
(where N is the unit number 0–7). Make a note
DA 00N
of this touchpad unit number.
9.
Check the unit numbers of all other existing touchpads
and write them down.
10. Check the unit number DIP switches on other bus
devices (ESM, HIM, etc.) and make a note of their
respective unit numbers.
11. Connect the wiring harness to one new touchpad.
12. Put the new touchpad into the manual configuration
mode by pressing and holding the touchpad D and 6
buttons until the display shows
001).
13. Press BYPASS and the display shows
14. Enter a unit number different from that of the existing
touchpads and any other bus devices in the system by
pressing any of the touchpad buttons numbered 0
through 7.
15. Press BYPASS then STATUS to lock in and display
the new unit number for the touchpad.
16. Disconnect this touchpad and repeat steps 11 through
16 for any other new alphanumeric touchpads. Be sure
to disconnect each touchpad after assigning its unit
number.
17. After assigning unit numbers to all the new touchpads,
connect each touchpad to its respective wiring harness.
18. Set the RUN/PROGRAM switch to RUN. All touch-
pads should display
1 - OFF
SuperBus® 2000 2 x 20 VFD Alphanumeric Touchpad
or
(1 blink-
1-OFF
TOUCHPAD OPTIONS
.
UNIT
DA 001
(unit number
ENTER _
.
.
19. Set the RUN/PROGRAM switch to PROGRAM so the
panel can learn all bus device unit numbers. All touch-
pads should display
PROGRAM MODE
20. Set the RUN/PROGRAM switch to RUN.
21. At each touchpad, verify correct operation by pressing
STATUS. The display should show the current system
status.
Powering up Concord Panels with Software
Version 2.0 or Newer and Concord Express Panels
1.
Verify that all wiring between the panel and touchpad is
correct.
2.
Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show "SCANNING
BUS DEVICES," then a date and time display.
Verify correct operation by pressing ‚. The display
3.
should show the current system status.
Note
If after pressing
the touchpad does not display the
current system status, see "Troubleshooting."
Powering up Concord Panels with Software
Versions 1.0–1.6
First Touchpad
1.
Verify that all wiring between the panel and touchpad is
correct.
2.
Check the unit number DIP switches on all other bus
devices (ESM, HIM, etc.) and make note of their
respective unit numbers.
Note
Touchpads default to unit number 001 when first
installed. If possible, leave this unit number open. If
unit number 001 is not available, or there are multiple
touchpads installed see the section "Additional
Touchpads" below.
3.
Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show "SCANNING
BUS DEVICES," then a date and time display.
Verify correct operation by pressing ‚. The display
4.
should show the current system status.
Note
If after pressing
the touchpad does not display the
current system status, see "Troubleshooting."
Additional Touchpads
1.
Verify that all wiring between the panel and touchpad is
correct.
2. Check the unit number DIP switches on other bus
devices (ESM, HIM, etc.) and make a note of their
respective unit numbers.
3.
Connect the panel battery and plug in the panel trans-
former. Alphanumeric touchpads show "SCANNING
BUS DEVICES," then a date and time display.
Power Up and Bus Communication
.