Mounting the Touchpad

3.
Insert the touchpad wiring harness connector onto the
pins located on the rear of the unit. Make sure the yel-
low wires are to the left (see Figure 5).
PANEL SUPERBUS
HARNESS 49-462
OPTIONAL
N/O SWITCH
WITH MAGNET
SPLICE
2K OHM
Connect Shield
EOL RESISTOR
to Earth Ground
OPTIONAL
SHIELDED
N/C SWITCH
CABLE
WITH MAGNET
YELLOW
Figure 5. Wiring the Touchpad to Advent Panels
Mounting the Touchpad
1.
Align the slots on the touchpad with the slots on the
back-plate. Insert the mounting tabs into the mounting
slots and press the keypad toward the wall/gang box.
2.
Tighten the two bottom screws.
Setting Touchpad Unit Numbers
Note
In multiple partition systems all new touchpads default
to partition 1. To change partition assignment please
see specific panel Installation Instructions . All
partitions must be disarmed before entering program
mode.
Panels automatically assign or learn the unit numbers of
each bus device upon power up or entering programming
mode. SuperBus 2000 panels (Advent panels and Concord
panels with software version 2.0 or newer) automatically
assign different unit numbers to each SuperBus 2000 mod-
ule. SuperBus panels (UltraGard panels and Concord panels
with software versions 1.0–1.6) do not automatically assign
different unit numbers to each SuperBus 2000 module. For
4
TO ADDITIONAL
SUPERBUS
TOUCHPADS
AND/OR
MODULES
WIRING
NOT
USED
TAB
SLOT (3)
TOUCHPAD
WIRING HARNESS
49-430
8543109C.DSF
these panels, alphanumeric touchpads default to 001. If
desired or necessary, the unit number must be manually
changed.
Guidelines for Assigning Alphanumeric Touchpad
Unit Numbers (Concord panels with software
versions 1.0–1.6 and UltraGard panels)
Use the following guidelines to avoid communication con-
flicts between bus devices and the panel:
Always start with one touchpad connected to the panel
and make sure it is working properly before connecting
additional touchpads.
Whenever possible, such as in new installations, assign
alphanumeric touchpad unit numbers before beginning
all other panel programming.
Other bus devices with device unit number DIP
switches (ESM, HIM, etc.) must be set to the desired
unit number before applying power and entering
program mode.

Power Up and Bus Communication

Powering Up UltraGard Panels
First Touchpad
1.
Disconnect all bus device wiring from the panel except
for the touchpad location closest to the panel.
2.
Verify that all wiring at the panel and touchpad wiring
harness is correct.
3.
With the panel power switch off, connect the panel bat-
tery and plug in the panel AC power transformer.
4.
Set the panel RUN/PROGRAM switch to RUN.
5.
Turn on the panel power switch.
6.
Put the touchpad into the manual configuration mode
by pressing and holding the touchpad D and 6 buttons
until the display shows
7.
Set the panel RUN/PROGRAM switch to PROGRAM
and the display should read
8.
Verify correct operation by pressing STATUS or
BYPASS. The display should show a different menu
item for each button pressed.
If your installation only calls for one alphanumeric touch-
pad, you may proceed with other system programming. If
you have more alphanumeric touchpads to connect and
assign device addresses, use the following procedure before
proceeding with any other system programming.
SuperBus® 2000 2 x 20 VFD Alphanumeric Touchpad
(unit number 001).
DA 001
PROGRAM MODE
.