ITI 60-804-04 - Concord LCD/VFD Alphanumeric SuperBus Keypad Installation Instructions Manual page 3

2x20 vfd aplhanumeric touchpad
Table of Contents

Advertisement

Wiring Panels
UltraGard Panels
1.
Connect the touchpad wiring to the panel terminals as
shown in Figure 3. Wire multiple touchpads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 3 (unsuper-
vised in UltraGard systems).
Note
The optional touchpad hardwire input must be added
to panel memory. See the UltraGard panel Installation
Instructions or Reference Manual for setting the con-
figuration.
3.
Insert the touchpad wiring harness connector onto the
pins located on the rear of the unit. Make sure the yel-
low wires are to the left.
DC
OUT
12
OPTIONAL
SWITCH
WITH MAGNET
(Not to be used in UL
listed installations)
Connect Shield To Earth Ground
SHIELDED
CABLE
YELLOW
WIRING HARNESS
49-430
Figure 3. Wiring the Touchpad to UltraGard Panels
Concord/Concord Express Panels
1.
Connect the touchpad wiring to the panel terminals as
shown in Figure 4. Wire multiple touchpads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 4.
Concord Express Systems- Wire a 2K ohm EOL resis-
tor (49-467) in series with normally closed switches
and in parallel with normally open switches (see
Figure 4).
SuperBus® 2000 2 x 20 VFD Alphanumeric Touchpad
CONTROL PANEL
BUS
BUS
A
GND
B
13
14
15
BLACK
WHITE
GREEN
RED
NOT
USED
TAB
SLOT (3)
8557148B.DS4
Concord Systems with software version 2.0 or newer-
Wire a 2K ohm EOL resistor (49-467) in series with
normally closed switches and in parallel with normally
open switches (see Figure 4).
Concord Systems with software versions 1.0–1.6 - This
switch must be unsupervised and a resistor must not be
used.
Note
The optional touchpad hardwire input must be added
to panel memory. See the Concord/Concord Express
panel Installation Instructions for setting the
configuration.
3.
Insert the touchpad wiring harness connector onto the
pins located on the rear of the unit. Make sure the yel-
low wires are to the left, as shown.
OPTIONAL
N/O SWITCH
WITH MAGNET
2K OHM
EOL RESISTOR
(Concord 2.0 or later
and Concord
Connect Shield
Express panels)
to Earth Ground
OPTIONAL
SHIELDED
N/C SWITCH
CABLE
WITH MAGNET
YELLOW
Figure 4. Wiring the Touchpad to Concord and
Concord Express Panels
Advent Panels
1.
Splice the touchpad wiring to the panel SuperBus wir-
ing harness as shown in Figure 5. Wire multiple touch-
pads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow wires on the touchpad wiring harness. Wire a
2K ohm EOL resistor (49-467) in series with normally
closed switches and in parallel with normally open
switches (see Figure 5).
Note
The optional touchpad hardwire input must be added
to panel memory. See the Advent panel Installation
Instructions for setting the configuration.
PANEL TERMINALS
+12V
BUS
BUS
GND
BUS
A
B
3
4
5
6
WHITE
GREEN
RED
BLACK
NOT
USED
TAB
SLOT (3)
TOUCHPAD
WIRING HARNESS
49-430
8557155B.DSF
Wiring
3

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for ITI 60-804-04 - Concord LCD/VFD Alphanumeric SuperBus Keypad

This manual is also suitable for:

Superbus 2000 60-804Superbus 2000 60-810