f-01-05
F-02-X ACAI Operation & Min. Unit Weight
f-02-01
f-02-02
f-02-03
ID Memory contents.
The scale ID memory can contain unit weights with tare
weights and comparator limits, or just unit weights alone.
00
ID memory contains the unit weight only.
You select which data to be stored by keying in a
Tare Weight
0 or 1 for the data: tare weight or comparator
limits.
00
Example: Key in 1
contains the unit weight and comparator limits.
Comparator limits
ACAI Mode When Unit Weight entered by Sample Pieces.
0
ACAI is disabled.
1
ACAI automatic Operation.
2
ACAI Manual Mode (using the ENTER key).
ACAI Mode When Unit Weight entered by Keyboard or ID.
0
ACAI is disabled.
ACAI Manual Mode (using the ENTER key). This setting
1
works when f-02-01 setting is not "0".
2
ACAI Automatic obeys f-02-01 setting.
Minimum Unit Weight.
The factory setting may be different for some countries.
0
1/5 d
1
1/100 d
0 to display 10, ID memory
(1d=1 weighing display division)
32