Fixed an issue where SAS port values were reported incorrectly.
•
Fixed issues with cold temperature monitoring.
•
Fixed an issue where a drive that reports a SMART error may not be downed appropriately.
•
Fixed a problem where a drive failure during initialization could cause a controller to crash.
•
Fixed a problem where a controller was brought down by a disk reset from the partner controller.
•
Fixed the licensing engine to prevent an invalid license from loading.
•
Fixed an issue where an uncorrectable ECC error caused a controller to crash.
•
Fixed an issue where a controller would stop responding when disks with media errors are in the
system.
•
Fixed an issue that lead to a vdisk faulting when controller A was replaced.
•
Fixed an issue where a vdisk using mirroring would fail to initialize when the maximum size was
requested.
•
Fixed a problem where a controller crash could be triggered by switching the owning controller
of a vdisk when snapshot volumes were resident on the vdisk.
•
Fixed an issue where the controller would stop responding when a snapshot with a duplicate name
was requested.
•
Fixed an issue where a RAID 10 vdisk in quarantine had a utility would fix a parity error even
though there was a missing member of the vdisk.
•
Fixed a problem where an erroneous SuperCap failure was reported.
•
Fixed a rare issue where controller temperature was displayed incorrectly .
•
Fixed an issue where the default LUN was not released for reuse when the owning volume was
deleted in a single controller array.
•
Fixed an issue of inconsistent behavior when moving drives from one drive enclosure to another
drive enclosure.
•
Fixed an issue on RAID 10 and RAID 50 vdisks that kept spares from being deleted.
•
Fixed an issue that lead the enclosure health status to be reported incorrectly.
•
Improved the initialization time for RAID 1 and RAID 10 vdisks.
•
Fixed an error on the iSCSI controller where a controller pair would lose connection and force
one of the controllers to shut the other down.
•
Fixed an issue where LUNs were presented in both PDA (Peripheral Device Addressing) and VSA
(Volume Set Addressing) modes.
•
Fixed an issue with SNMP incorrectly reporting certain traps.
•
Fixed a problem where the loop IDs of the controllers were not properly displayed.
•
Fixed an issue where part and serial number were not displayed correctly.
•
Fixed a problem where online help was formatting incorrectly (CLI).
•
Added a function to allow SNMP test traps to be sent (CLI).
•
Fixed a problem that caused enabling NTP to fail because of an improper condition (CLI).
•
Fixed an issue where set disk-parameters was not accepting valid input (CLI). (Example:
set disk-parameters smart off)
•
Fixed an issue where a set job-parameters utility-priority command returned an
error of "Error: Invalid FC topology" (CLI).
•
Fixed an issue that lead to inconsistent vdisk status reporting (CLI).
•
Fixed various cosmetic issues (GUI).
•
Fixed an issue where changing volume names allowed the user to change the name to a volume
that is already in use (GUI).
•
Fixed Help to provide the correct location for Save Logs feature (GUI).
HP StorageWorks MSA2000 G2 Firmware Release Notes
5
Need help?