Zonesets containing domain/port number zones while in Open Fabric interop mode no longer
cause zoning to hang
When directors and edge switches in a fabric were configured for Open Fabric 1.0
interop mode, and the fabric's zoneset contained a zone with members defined by
domain/port number instead of World Wide Name, activating changes to the zoneset
could cause the Zone Manager to hang. When this occurred, the Zone Manager could
hang indefinitely, preventing any further zone activities from any management location.
It should be noted that domain/port number zones are not supported in Open Fabric
1.0 interop mode, and are ignored. The Zone Manager will no longer hang under these
conditions, and these zones are still ignored in Open Fabric 1.0 interop mode.
Occasional Ethernet hang issue is resolved
Under certain conditions, the Ethernet communications could intermittently hang on
director 2/140, edge switch 2/24, and edge switch 2/12. This issue has been
corrected.
Features not supported in this release
The following director and edge switch feature is not supported in this release:
SANtegrity Authentication
The following HAFM features are not supported in this release:
SANtegrity Security Center
Group Configuration Manager
These features are described in the documentation released with firmware 07.00.00 and
HAFM 08.06.00. Some of these features may be available in a future release.