HP StorageWorks 2/140 - Director Switch Release Note page 18

Fw 07.01.02/hafm sw 08.06.00 hp storageworks director release notes (aa-rtdvh-te, august 2005)
Hide thumbs Also See for StorageWorks 2/140 - Director Switch:
Table of Contents

Advertisement

To configure this feature, users set policies with thresholds based on the number of
port events occurring during a set time period. If a port generates enough events to
exceed the policy threshold, the port is automatically blocked and the user is notified.
Transmit and receive traffic is disabled until the user can investigate, solve the problem,
and manually unblock the port.
Embedded Audit Log
The Audit log is a new log available through CLI and EWS. This is not the same Audit
Log available through HAFM. The log records all configuration changes to the switch to
provide data for analyzing problems caused by configuration changes.
Embedded Port Log
The Embedded Port Log is a new log that records all Fibre Channel traffic from or to
the embedded port. This log is actually implemented as two logs, one that allows entry
wrapping and one that stops adding entries when filled. The logs allow filtering based
on Class F frames, as well as by port number, to isolate specific events or problems.
This feature is intended for advanced users to diagnose and troubleshoot traffic problems
within a SAN. The Embedded Port Log is available via EWS, CLI, and HAFM.
Embedded Fabric Log
The switch-based fabric log records events related to the following services:
Fabric Controller
Path Selection
Login Server
Name Server
The Fabric log is actually implemented as two logs, one that allows entry wrapping and
one that stops adding entries when filled. This log is intended to provide information for
analyzing fabric and switch behaviors and problems. The Fabric log is available via
EWS, CLI, and HAFM.
OSMS change
Open Systems Management Server (OSMS) is now available as a standard feature.
OSMS can be enabled/disabled via EWS, Command Line Interface (CLI), and HAFM.
Default zone is disabled by default
The default zone on the Director 2/64 and the Director 2/140 is disabled by default.
Zoning must be configured in order for any devices connected to the director to
communicate.
16