Table 3 Permissible Internal and V-VOL Combinations
Source Volume
Internal Volume
V-VOL in Normal state
V-VOL in Blocked state due to full
capacity
The migration plan might not be executed if the storage system is experiencing a heavy workload.
When you specify a Thin Provisioning virtual volume or an internal volume which is used for the
Continuous Access Synchronous pair as a source volume, see the
specifying a target volume. The Continuous Access Synchronous pair combination of an internal
volume as a P-VOL and a Thin Provisioning virtual volume as an S-VOL is not recommended.
If the capacity of a Thin Provisioning virtual volume is increasing, this volume cannot be specified
as the source or target volume in an Auto LUN plan. It will also be impossible to reserve or remove
the reserve attribute for a virtual volume whose capacity is increasing. You must ensure that the
capacity of a Thin Provisioning virtual volume is not increasing if you plan on using that virtual
volume in an Auto LUN plan.
Auto LUN with Continuous Access Synchronous and Continuous Access
Journal V-VOLs
When the selected source volume is a P-VOL or an S-VOL of a Continuous Access Synchronous or
Continuous Access Journal pair consisting of internal volumes and/or Thin Provisioning virtual
volumes, there are some target volume candidates that should not be considered. The following
table lists the possible Internal/V-VOL - Continuous Access Synchronous/Continuous Access Journal
pair combinations, and tells which type of volume should not be considered as a target volume
based on the Continuous Access Synchronous/Continuous Access Journal pair combination and
the selected source volume.
Table 4 Poor Target Volume Candidates for Cnt Ac-S/Cnt Ac-J Pair Combinations
Continuous Access Synchronous or
Continuous Access Journal Pair
Internal P-VOL, Internal S-VOL
Internal P-VOL, V-VOL S-VOL
Internal Volume as Target Volume
A migration plan can be created.
A migration plan can be created.
A migration plan can be created.
Source Volume
Candidate
Internal P-VOL
Internal S-VOL
Internal P-VOL
V-VOL S-VOL

Auto LUN with Continuous Access Synchronous and Continuous Access Journal V-VOLs

V-VOL in Normal State as Target
Volume
A migration plan can be created.
If operations change the configuration
of the storage system after the initial
volume migration, any subsequent
volume migration must be executed at
an interval which is calculated by the
following formula:
(Pool_Capacity x 3 (seconds)) + 40
(minutes)
A migration plan can be created. A
warning message appears if there is a
possibility that the data size may
exceed the pool threshold after
migration.
A migration plan can be created. A
warning message appears if there is a
possibility that the data size may
exceed the pool threshold after
migration.
Table 4 (page 15)
table for
Poor Target Volume Candidate
None
V-VOL
Internal volume
V-VOL
15

Advertisement

Table of Contents
loading

Table of Contents