IBM 3390 Concurrent Copy volumes
Volumes reserved by a migration program other than Auto LUN
Volumes undergoing a Quick Format operation
Volumes in an abnormal or inaccessible condition (such as, pinned, tracked, or fenced)
External Storage Access Manager P-VOLs or S-VOLs
The following table lists the volumes and volume types that can and cannot be considered as
candidates for source and/or target volumes for an Auto LUN operation. The table is categorized
by program product.
Table 2 Candidates for Source and Target Volumes by Program Product
Program Product
Thin Provisioning
Continuous Access
Synchronous
Continuous Access
Synchronous Z
Continuous Access Journal
and Continuous Access
Journal Z
Continuous Access Journal
12
Requirements
Volume Type/Status
V-VOL
Pool volume
A volume in PSUS, PSUE, or
PAIR status
Deleted pair volumes from
MCU
Deleted S-VOL from MCU
Deleted P-VOL from RCU
A volume in suspended,
simplex, or duplex status
An external M-VOL
An external R-VOL
A data volume pair
A journal volume
A primary volume in any
status
A secondary volume in PSUS
status
A volume in COPY or PAIR
status
Source Volume Candidate?
Yes
NOTE:
The maximum
capacity is 4 TB.
No
Yes
Yes, if volumes are in SMPL
status
Yes, if volume is in SMPL
status
Yes, if volume is in SMPL
status
Yes
Yes, if volume is in
suspended status
Yes, if volume is in simplex
status
Yes.
NOTE:
The target volume
must be in the same CLPR.
No
Yes.
NOTE:
The target volume
must be in the same CLPR.
Yes.
NOTE:
The target volume
must be in the same CLPR.
No
Target Volume Candidate?
Yes, but the target volume
may not be associated with
the same Thin Provisioning
pool as the source volume
NOTE:
The maximum
capacity is 4 TB.
No
No
No
No
No
No
No
No
No
No