PLC-XU300/350 Basic Serial Command Specifications

7.4. Input Mode Read Command

Command
"CR1" [CR]
Detail
Get the selected Input No.
Acceptable
Response
%1
Unacceptable

7.5. Lamp Time Read Command

Command
"CR3" [CR]
Get the total lamp running hours (Not actual lamp used hour, but Eco mode
Detail
corresponding value).
Acceptable
Response
%1
Unacceptable

7.6. Setting Read Command

Command
"CR4" [CR]
Detail
Get screen setting status such as Ceiling / Rear.
Acceptable
Response
%1
Unacceptable

7.7. Temp Read Command

Command
"CR6" [CR]
Get the temperature data inside the projector.
Detail
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Acceptable
%1
%2
Response
%3
Unacceptable
"%1" [CR]
"1" = Computer 1 is selected
"2" = Computer 2 is selected
"3" = Video is selected
"4" = Wired is selected
"5" = Wireless/Viewer is selected
"?" [CR]
"%1" [CR]
Shows the time period with 5 digits numbers.
Exampleÿ "00410"[CR] ÿ e ÿ e ÿ e ÿ e shows 410 hours
"?" [CR]
"%1" [CR]
"11"[CR] = Normal Screen Setting
"10"[CR] = Picture is top/bottom reversed.
(Status: Rearÿ Ceiling ON)
"01"[CR] = Picture is left/right reversed. (Status: Rear ON)
"00"[CR] = Picture is top/bottom and left/right reversed.
(Status: Ceiling ON
"?" [CR]
"%1_%2_%3" [CR]
%1ÿ Temperature of sensor 1
%2ÿ Temperature of sensor 2
%3ÿ Temperature of sensor 3
Temperature data is shown as "00.0".
When the temperature goes down to -, the first character
becomes "-" instead of a space, like "-05.5" [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes "E" like"E00.0" [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
"_31.5 _ _35.2 _ _33.4"[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
"ÿ "[CR]