PLC-XU300/350 Basic Serial Command Specifications

6.34. ON START Setting Command

Command
"C28" [CR]
Enable Power ON Start.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable

6.35. ON START Cancel Command

Command
"C29" [CR]
Disable Power ON Start.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable

6.36. Power Management Ready Command

Command
"C2A" [CR]
Set Power Management to Ready mode.
Detail
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Acceptable
Response
Unacceptable

6.37. Power Management OFF Command

Command
"C2B" [CR]
Set Power Management to OFF mode.
Detail
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Acceptable
Response
Unacceptable

6.38. Power Management Shut down Command

Command
"C2E" [CR]
Set Power Management to Shut down mode.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable

6.39. D.ZOOM + Command

Command
"C30" [CR]
Enter Digital Zoom mode and expand image size.
Detail
This command works the same way as "D.ZOOM ▲" button of the remote control.
Acceptable
Response
Unacceptable
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]