protection measures should be taken.
Ensure the rack and device are well earthed.
■
Make sure the power socket has a good contact with the ground.
■
Keep a reasonable cabling system and avoid induced lightning.
■
Use the signal SPD (Surge Protective Device1 when wiring outdoor.
■
Note: For detailed lightning protection measures, please refer to Chapter 3
Lightning Protection.
Installation Site
TL-SG5428
When installing the device on a rack or a flat workbench, please note the following
items:
TL-SG5428
The rack or workbench is flat and stable, and sturdy enough to support the weight of
■
5.5kg at least.
The rack or workbench has a good ventilation system. The equipment room is well
■
ventilated.
The rack is well grounded. Keep the power socket less than 1.5 meters away from the
■
device.
112
Installation Tools
Phillips screwdriver
■
ESD-preventive wrist wrap
■
Cables
■
Note: These tools are not provided with our product. If needed, please self purchase
them.
112
Product Installation
Desktop Installation
■
To install the device on the desktop, please follow the steps below:
1.
Set the device on a flat surface strong enough to support the entire weight of the
device with all fittings.
2.
Remove the adhesive backing papers from the rubber feet.
L2 Managed Switch