6913-System Board Main
Voltage Failure Detected
6914-Forced System Shutdown
from an over-temp fault
condition on previous boot
6915-CPU not detected on
previous attempt to boot.
6916-CPU Heatsink not
properly attached
6918-System Real Time Clock
Oscillator not running within
tolerance.
6919-Temperature and Power
Monitoring Hardware failure
6920-Processor in Force-
Throttle Mode
6921-Blade System
Management Controller
firmware update failed
6922-Blade temperature
detected to be below 0 degrees
Celsius
6923-CPU Temperature
Monitoring Hardware failure
6924-Graphics Temperature
Monitoring Hardware failure
60
Appendix C POST Error Messages
Red
Potential enclosure or
blade PC issue.
Green
Internal temperature
exceeds specification.
Green
The CPU was not
detected on previous
boot attempt.
Amber
The heatsink is loose.
Amber
System Real Time
Clock Oscillator not
running within
tolerance.
Red
Blade PC failure.
Amber
Enclosure or
environmental issue.
Amber
The flashing process
was interrupted.
Amber
The blade PC is
operating in
temperatures below
specification.
Red
CPU temperature
monitoring hardware
has failed.
Red
System graphics
temperature
monitoring hardware
has failed.
Swap the blade PC to a different bay in the
enclosure and retest.
Put the blade PC into a different enclosure.
If the blade PC works in a different
enclosure, troubleshoot the original
enclosure. For troubleshooting information,
see
Troubleshooting on page
Replace the blade.
Ensure that the system fans are functioning
properly and that the enclosure has
adequate ventilation.
Check the processor heat sink.
Replace the blade PC.
Informational message only.
Remove the blade PC and check if heatsink
is loose or not present. Tighten CPU
heatsink screws to 8 inch-lbs of tension.
Replace the blade PC if the messages
persist.
Replace CMOS battery.
If the problem persists, replace the blade
PC.
Replace the blade PC.
Ensure the enclosure health LED is green
and health status is ok. If LED not green,
troubleshoot the enclosure. For
troubleshooting information, see
Troubleshooting on page
If the enclosure health LED is green, check
heatsink installation and operating ambient.
Make sure every enclosure slot is filled with
a blank or a blade PC.
Re-flash the BMC firmware image.
Check operating ambient. Operate the blade PC
within environmental specifications.
Replace the blade PC.
Replace the blade PC.