Download Print this page

HP BL680c - ProLiant - G5 Getting Started Manual page 5

Hp integrated vmware esxi 3.5 update 5 getting started guide
Hide thumbs Also See for BL680c - ProLiant - G5:

Advertisement

4.
If you install to flash media (USB or SD card,) you must install the flash media
into the internal port on your ProLiant server.
For instructions on how to access the internal flash media (USB or SD card) port,
see the server documentation included with your server.
For hardware requirements, see the server documentation included with your
server.
5.
Access the server console in one of the following ways:
o
Locally—Use your local keyboard and monitor.
o
Remotely—Use iLO Integrated Remote Console remotely from a network
client using a web browser.
Remote setup requires HP iLO2 Advanced Pack, which is sold separately for
HP ProLiant ML and DL servers. The remote graphics capability is included
with BL servers.
IMPORTANT: After you boot up the server, you must press the
correct function key when prompted to enter setup mode to
configure boot order, configure hardware virtualization, and
configure iLO and the Smart Array controller. Familiarize yourself
with the following steps and prompts; each prompt is available
for only a few seconds during the boot process.
If you are installing to the hard drive, proceed to step 7.
6.
To enable use of flash media (USB flash drive or SD card):
a. Configure your flash device to boot before the hard drive. By default, flash
media is configured to boot before the hard drive.
b. Boot the server, and then press F9 to enter ROM Based Setup Utility (RBSU).
c. Scroll down to Standard Boot Order (IPL), and press Enter.
d. To modify the boot order, select the device you want to move, and then press
Enter. A menu appears to change the device boot order.
e. Ensure the flash media is set to boot before the hard drive.
7.
Enable CPU virtualization.
For CPU specific virtualization capabilities, you can select Intel® Virtualization
Technology or AMD® Virtualization. You must perform this step for supporting
Windows® 64 bit operating systems and all guest 64 bit operating systems, such
as Linux.
a. If you are not in RBSU, boot the server, and then press F9 to enter ROM
Based Setup Utility (RBSU).
b. Scroll down to Advanced Options, and press Enter.
c. Scroll down to Processor Options, and press Enter.
d. Scroll down to the servers supported processor (either Intel® Virtualization
Technology or AMD® Virtualization), and press Enter.

Advertisement

loading

This manual is also suitable for:

Ml350 - proliant - g6Bl480c - proliant - 4 gb ramBl460c - proliant - g5Vmware esxi 3.5