Step 3-1
Square
Hanger
Motor
Assembly
Step 3-2
Step 3-3
#8-32 x 1" Screw
3 • Assembling and Hanging the Fan
3-1 . Position the square hanger so that the green ground wire attached
to the square faces out of the large opening in the metal bracket .
3-2 . Holding the wires out of the way, lift the motor assembly and
place the square hanger into the opening in the ceiling plate .
WARNING: Make sure the square hanger can not rotate in the
metal bracket . Failure to do so could result in the fan falling .
3-3 . Install two locking screws through the holes in the side of the
metal bracket to secure the square hanger .
Green
Ground Wire
Green
Ground Wire
Locking Screw
8
42823-01 • 04/13/10 • Hunter Fan Company