Samsung AQ09A6MAF/KCV Owner's Instructions Manual page 27

Split type air conditioner (cool and heat)
Table of Contents

Advertisement

MODEL
Capacity Cooling
Performance
Ratings
Capacity Heating
HSPF
SEER
Moisture Removal
Air FLOW(Cooling, HIGH)
Air FLOW(Heating, HIGH)
Sound Rating-Outdoor
Power source
Electrical
Data
Min.Ampacity
Cooling Watts
Heating Watts
Connections
Refrigeration
Lines
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
INDOOR UNIT
Dimensions
& Weight
W X H X D
Net Weight
OUTDOOR UNIT
W X H X D
Net Weight
AQ18A9(0)RCF
Btu/h
17500
Btu/h
19000
6.8
10.0
Pts/h
4.5
CFM
457
486
CFM
58
dB
208-230V~, 60Hz
A
7.6
W
1700
W
1730
Flare
inch(mm)
1
(6.35)
4
inch(mm)
1
(12.70)
2
3
24
(7.5)
ft(m)
4
1
49
(15.0 )
ft(m)
4
ft(m)
23(7.0)
AQ18A9(0)RCF
1
x
42
11 x 8
inch(mm)
2
(1080 x 275 x 204)
Ibs(kg)
29.7(13.4)
UQ18A9(0)RCF
3
5
31 24
x
x 12
8
8
inch(mm)
(787 x 620 x 320)
101.4(45)
Ibs(kg)
AQ24A1(2)RC
AQ30C1(2)BC
23500
24000
6.8
10.0
5.4
477
512
59
208-230V~, 60Hz
208-230V~, 60Hz
10.5
2350
2400
Flare
(6.35)
1
4
(15.88)
5
8
1
16
(5.0)
2
1
65
(20.0)
2
1
(8.0 )
26
4
AQ24A1(2)RC
AQ30C1(2)BC
1
5
x
42
11 x 8
50
2
(1080 x 275 x 204)
(1279 x 345 x 229)
29.7(13.4)
UQ24A1(2)RC
UQ30C1(2)BC
5
1
1
5
34
x
25
x
12
34
8
8
4
8
(880 x 638 x 310)
(880 x 890 x 310)
138.9(62)
30000
30000
6.8
10.0
7.2
671
706
58
14
3100
3100
Flare
(6.35)
1
4
(15.88)
5
8
3
24
(7.5)
4
1
65
(20.0)
2
1
(8.0 )
26
4
5
x
x 9
13
8
8
44.1(20)
1
x
x 12
35
4
183(81)
27
E-

Advertisement

Table of Contents
loading

Table of Contents