HEATING MODE
GAS MANIFOLD PRESSURE "W.C." ______
1
2
COMBUSTION SAMPLE CO
INDOOR BLOWER AMPS ______
3
TEMPERATURE RISE
4
Supply Duct Temperature
Return Duct Temperature
Temperature Rise
TOTAL EXTERNAL STATIC
5
Supply External Static
Return External Static
Total External Static
6
CONDENSATE LINE
Leak Free
7
VENT PIPE
Leak Free
Combustion CO
2
9
Blower Motor Amps
3
Contractor's:
Name______________________________________Telephone________________Checklist Completed____________________
Job Address_______________________________________________________Technician's Name___________________________________
506725-01
UNIT OPERATION
%
CO _____ PPM
______
2
______
_
______
______
=
______
+
______
=
______
2
7
Thermostat
6
SUPPLY
AIR
8
Gas Manifold Pressure
1
Issue 1109
COOLING MODE
3
INDOOR BLOWER AMPS ______
TEMPERATURE DROP
4
Return Duct Temperature
Supply Duct Temperature
Temperature Drop
5
TOTAL EXTERNAL STATIC (dry coil)
Supply External Static
Return External Static
Total External Static
DRAIN LINE
8
Leak Free
THERMOSTAT
9
Adjusted and Programmed
Explained Operation to Owner
RETURN AIR
______
_
______
______
=
______
______
+
=
______
Temperatures
4
Duct Static
5
Page 47 of 48