Connecting The San I/O Module To The Ethernet Network - Brocade Communications Systems PowerEdge M420 Quick Start Manual

Brocade 4424 blade server san i/o quickstart guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

4. Use the appropriate CLI commands to change the IP address of the selected SAN I/O module. Refer to your
Blade Server Enclosure CLI documentation.
Using the CMC GUI to set the IP address
To change the IP address, use the following steps:
1. Open the CMC application's Setup tab.
2. Enter the new information in the IP Address, Subnet Mask, and Gateway fields as appropriate and click Apply.
3. To enable DHCP, select DHCP Enabled and click Apply.
FIGURE 1
CMC Setup Tab
NOTE
Refer to the documentation for the CMC GUI application for additional detail.

Connecting the SAN I/O Module to the Ethernet network

Once you have successfully set the appropriate IP address of the SAN I/O Module, you can establish an Ethernet
connection through the Chassis Management Controller (CMC) to a remote management workstation for any
additional configuration. The management workstation must be on the same Ethernet subnet as the CMC.
NOTE
Ensure that the SAN I/O Module is not being modified from any other connection until configuration is complete.
4424 QuickStart Guide