Dell PowerEdge C6220 Using Instructions page 56

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C6220:
Table of Contents

Advertisement

FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC
Table 1-37. Sensory Device Commands (NETFUN: 04H)
Command
Get Device SDR Info
Get Device SDR
Reserve Device SDR Repository
Get Sensor Reading Factors
Set Sensor Hysteresis
Get Sensor Hysteresis
Set Sensor Threshold
Get Sensor Threshold
Set Sensor Event Enable
Get Sensor Event Enable
Set Sensor Reading and Event Status
Re-arm Sensor Events
Get Sensor Event Status
Get Sensor Reading
Set Sensor Type
Get Sensor Type
Table 1-38. Event Commands (NETFUN: 04H)
Command
Set Event Receiver
Get Event Receiver
Platform Event
56
Manual\BMC\C6220_BMC_HOM_section1.fm
NetFn
CMD
S/E
20h
S/E
21h
S/E
22h
S/E
23h
S/E
24h
S/E
25h
S/E
26h
S/E
27h
S/E
28h
S/E
29h
S/E
30h
S/E
2Ah
S/E
2Bh
S/E
2Dh
S/E
2Eh
S/E
2Fh
NetFn
CMD
S/E
00h
S/E
01h
S/E
02h
O/M
Supported
O
No
O
No
O
No
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
O
Yes
M
Yes
O
No
O
No
O/M
Supported
M
Yes
M
Yes
M
Yes