Threshold Settings and Converting Formulas

Table 1-33. Threshold Settings and Converting Formulas
Sensor
Sensor Name
Number
Fan
01h
FCB FAN1
02h
FCB FAN2
03h
FCB FAN3
04h
FCB FAN4
Voltage
14h
PS 12V
15h
PS 5V
16h
STBY 3.3V
51h
VCORE 1
38
Using the Baseboard Management Controller
The Converting Formula
Upper non-
Upper
recoverable
critical
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (Volts) = Raw_Data x 0.062
0xD8
0xD4
Actual_Reading (Volts) = Raw_Data x 0.026
0xD7
0xD3
Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6
0xD3
Actual_Reading (Volts) = Raw_Data x 0.0083
0xFF
0xFF
Upper
Lower non-
non-critical
recoverable
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xCF
0xAB
0xCD
0xA9
0xCD
0xA9
0xFF
0x00
Lower
Lower
critical
non-critical
0x0F
0x00
0x0F
0x00
0x0F
0x00
0x0F
0x00
0xAF
0xB4
0xAE
0xB3
0xAD
0xB3
0x00
0x00