FAN Control and Monitoring

The BMC receives all fan tachometers of the threshold base from the chassis
controller. The following is the table of the fan speed thresholds.
8 Sled SKU
Table 1-10. 8 Sled SKU Fan Thresholds
Fan Sensor
SYS FAN 1
SYS FAN 2
SYS FAN 3
SYS FAN 4
SYS FAN 5
SYS FAN 6
SYS FAN 7
SYS FAN 8
12 Sled SKU
Table 1-11. 12 Sled SKU Fan Thresholds
Fan Sensor
SYS FAN 1
SYS FAN 2
SYS FAN 3
SYS FAN 4
SYS FAN 5
SYS FAN 6
SYS FAN 7
SYS FAN 8
22
Sensor
LCT
Number
68h
0rpm
69h
0rpm
6Ah
0rpm
6Bh
0rpm
6Ch
0rpm
6Dh
0rpm
6Eh
0rpm
6Fh
0rpm
Sensor
LCT
Number
68h
0rpm
69h
0rpm
6Ah
0rpm
6Bh
0rpm
6Ch
0rpm
6Dh
0rpm
6Eh
0rpm
6Fh
0rpm
LNCT
UNCT
660rpm
N/A
660rpm
N/A
660rpm
N/A
660rpm
N/A
660rpm
N/A
660rpm
N/A
660rpm
N/A
660rpm
N/A
LNCT
UNCT
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
1140rpm
N/A
UCT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UCT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Advertisement