Dell PowerEdge C5125 Using Instructions page 14

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C5125:
Table of Contents

Advertisement

Table 1-4. LED Status
LED
Color
ID LED
Blue
Heartbeat
Green Off
LED
14
Status
Occurence
Off
Normal status (by IPMI
Chassis Identify
command or System
ID Button)
Solid On 1. Via IPMI chassis
command.
2. System id button
press.
Blinking Via IPMI Chassis
Identify command
BMC is not ready
Blinking BMC is ready
Note
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Turn on the ID LED.
1.ipmitool raw 0x00 0x04
0x3c 01
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60
sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)

Advertisement

Table of Contents
loading