Electrolux FEQ1442ES Installation Instructions Manual

Gas & electric drye

Advertisement

Quick Links

Installation
Instructions
Gas & Electric
Dryer
Pre-lnstallation Requirements ...................................
2
Electrical Requirements ...........................................
2
Ventilation System Requirements .............................
3-4
Exhaust System Requirements ..................................
4
Gas Supply Requirements ........................................
4
Location of Your Dryer .............................................
5
Mobile Home Installation .........................................
6
Rough-In Dimensions ...............................................
6-7
Unpacking .............................................................
7
Reversing Door Swing ..............................................
7-8
Electrical Installation ................................................
9
Grounding Requirements ..........................................
9
Electrical Connections--3-wire
.................................
10
Electrical Connections--4-wire
.................................
10
Gas Connection ......................................................
11
General Installation .................................................
11
Replacement Parts ..................................................
11
Before beginning
installation,
carefully
read these instructions.
This wilt simplify
the installation
and ensure
the dryer is installed
correctly and safely. Leave these instructions
near the Dryer after installation
for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANS!/NEPA 70.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and tile latest edition of the National
Fuel Gas Code ANS! Z223.1.
NOTE: Tile Dryer is designed under ANS! Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME USE
only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
Save These Instructions
'¢¢vv¢,zfrigidaire.com
P/N 134431700 (0405)

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux FEQ1442ES

  • Page 1 Pre-lnstallation Requirements ........Electrical Requirements ........... Ventilation System Requirements ......Exhaust System Requirements ........Gas Supply Requirements ........Location of Your Dryer ..........Installation Mobile Home Installation ......... Rough-In Dimensions ..........Instructions Unpacking ............. Reversing Door Swing ..........Electrical Installation ..........Grounding Requirements ..........
  • Page 2: What To Do If You Smell Gas

    POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, For your safety the information 60 Hz, Alternating Current. this manual must be followed to minimize the POWER SUPPLY CORD KIT - The dryer MUST employ a risk of fire or explosion or to prevent property 3-conductor power supply cord NEMA I0-30 type SRDT damage, personal injury or loss of life.
  • Page 3: System Requirements

    EXHAUST SYSTEM REQUIREMENTS MAX/MUM LENGTH of 4" (10.2 cm) Dia. Rigid Metal Duct Use only 4 inch (! 0.2 cm) diameter (minimum) rigid or VENT HOOD TYPE flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in (Preferred) operation.
  • Page 4 Although vertical orientation o f the exhaust system is 2. Tile gas supply line should be of 1/2 inch (127 cm) acceptable, certainextenuating c ircumstances couldaffect pipe. theperformance ofthedryer: 3. If codes allow, flexible metal tubing may be used to Only therigidmetal d uctworkshould beused.
  • Page 5 MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR FRONT Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm) Closet 0(0cm) 0(0cm) 15(38.1 cm) 1(2.54cm) Closet door ventilation required: 2 Iouvered openings each 60 square inches (387 square centimeters) -- 3 inches (7.6 cm) from bottom and top of door.
  • Page 6 Dryer tnstMtation Dimensions Free-Standin 9 & Under Counter Electrical supply 48.5" To clear open door on rear of unit (123.19cm) 0 o L_,#, _' Gas supply pipe on rear of unit '91.44cm) I.,T-. (5.72cm) \" .I.-.L- 2.25" 5.0" (12.7cm) Center line height •, right, left...
  • Page 7: Mobile Home Installation

    MOBILE HOME INSTALLATION Using the four shipping carton corner posts (two on each side), Dryer MUST be exhausted outside (outdoors, not beneath the carefully Jay the dryer on its left side and remove the foam mobile home) using metal ducting that will not support shipping base combustion...
  • Page 8 "Window Door" Reversal Instructions: 4. Remove 3. Remove 1. Open the dryer door. Rernovett/e four hinge hole plugs Handle Screws Plastic Plugs from the left side of the door opening. Place nearby for future installation NOTE: You may need a plastic knife to help pull out the plugs.
  • Page 9: Electrical Installation

    ELECTRICAL INSTALLATION 2. If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, ELECTR/C Dryer the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 10: Electrical Connections

    GREEN GREEN POWER CORD ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM EL ECTR/C Dryer ELECTRICAL CONNECTIONS Remove the screws securing the terminal block access cover and tile strain relief mounting bracket located on FOR 3-WIRE SYSTEM the back of the dryer upper corner. Install a U.L approved strain relief in the entry hole of ELECTR/C Dryer...
  • Page 11: Gas Connection

    GAS CONNECTION 5. Run the dryer through a cycle check for proper 1. Remove the shipping cap from gas pipe at the rear of operation. the dryer. NOTE: On gas dryers, before the burner will light, it is NOTE; DO NOT connect the dryer to L.R gas service necessary for the gas line to be bled of air.