Led Descriptions - Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual

Cisco nexus 5000 series hardware installation guide (ol-15902-01, november 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Nexus 5020 Switch
S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m

LED Descriptions

Table 1-3
Table 1-3
LED
Chassis
Fan module
Cisco Nexus 5000 Series Hardware Installation Guide
1-12
describes the LEDs for the Cisco Nexus 5020 switch.
LEDs for the Cisco Nexus 5020 Switch
Location
Function
Front and back
Chassis
of chassis
power and
health
Fan modules
Fan
(front)
module
health
indicator
Color
Status
Description
Green
Solid on
All diagnostics pass. The
module is operational.
Off
The module is not receiving
power.
Amber
On
The module is booting or
running diagnostics.
An over temperature condition
has occurred. The temperature
threshold has been exceeded
by a small value during
environmental monitoring.
Blinking
An over temperature condition
has occurred. The temperature
threshold has been exceeded
by a large value during
environmental monitoring.
If the module fails during
initial reset, the LED
continues to blink and the
module does not come online.
The module has runtime
failure and is brought offline.
Green
Solid on
All diagnostics pass. The
module is operational.
Off
The module is not receiving
power.
Amber
Solid on
The module is booting or
running diagnostics.
Amber
Blinking
If the module fails during
initial reset, the LED
continues to blink and the
module does not come online.
The module has runtime
failure and is brought offline.
Chapter 1
Product Overview
OL-15902-01

Advertisement

Table of Contents
loading