To configure FMS mode parameters
1. Click a FICON-enabled switch from the
2. Open the Switch Administration window as described on
3. Click the FICON CUP tab.
4. To enable or disable an FMS mode parameter, click the check box next to the parameter. A

Displaying code page information

The Code Page field identifies the language used to exchange information between the FICON
director and Host Programming. It is a read-only field in Web Tools, as it is set by Host Programming
only. When FMS mode is disabled, the code page is displayed as unavailable.
To display the code page information
1. Click a FICON-enabled switch from the
2. Open the Switch Administration window as described on
3. Click the FICON CUP tab.

Displaying the control device state

The control device is in either a neutral or a switched state. When it is neutral, the control device
accepts commands from any channel that has established a logic path with it and accepts
commands from alternate managers. When the control device is switched, it establishes a logical
path and accepts commands only from that logical path ("device allegiance"). Commands from
other paths cause a FICON CUP Busy Error. Most "write" operations from alternate managers are
also rejected.
Device allegiance usually lasts for a very short time. However, under abnormal conditions, device
allegiance can get "stuck" and fail to terminate. It might cause the switch to be unmanageable with
CUP, and you will continue to receive the FICON CUP Busy Error. In this case, you should check the
control device state and the last update time to identify if the device allegiance is stuck. The Web
Tools Switch Admin displays the control device state and last update time (see
page 220). You can click Refresh to get most recent update.
Web Tools Administrator's Guide
Publication Number: 53-1000435-01
The FICON CUP tabbed page displays, with the FICON Management Server subtabbed page in
front (see
Figure 99
on page 220). All attributes on this tab are read-only until FMS mode is
enabled.
marked check box means that the parameter is enabled. You cannot configure the User Alert
Mode parameter in Web Tools, as it is read-only.
The FICON CUP tabbed page displays, with the FICON Management Server subtabbed page in
front (see
Figure 99
on page 220). All attributes on this tab are read-only until FMS mode is
enabled.
The code page format is displayed in the Code Page field as shown in the example below:
Language used to exchange information with Host Programming: (EBCDIC)