Checking Leds; Setting The Ip Address - Cisco 9124 - MDS Fabric Switch User Manual

Fabric switch for hp c-class bladesystem
Hide thumbs Also See for 9124 - Cisco MDS Fabric Switch:
Table of Contents

Advertisement

Checking LEDs

See
Figure 6
to locate power-on LEDs.
Figure 6
Verifying power-on LEDs
Verify that the LEDs match the indicators described in
Table 7
Power-on LEDs
Item
Description
1
UID LED
module in the BladeSystem for replacement,
etc.
2
Health ID LED

Setting the IP address

Obtain the following items to set the IP address via a serial connection:
Computer with a terminal application (such as HyperTerminal in a Windows environment or
TERM in a UNIX environment
Null modem serial cable
Set the IP address:
1.
Verify that the enclosure is powered on.
2.
Identify the active OA in the BladeSystem.
3.
Connect a Null modem serial cable from your computer to the serial port of the active OA.
4.
Configure the terminal application as follows:
• In a Windows environment:
• Baud rate—9600 bits per second
• 8 data bits
• None (No parity)
• 1 stop bit
• No flow control
1
EXT 1
!
:
2
- used to help user locate a specific
EXT 2
EXT 3
EXT 4
Table
7.
Indicators
Off
Steady green light