Operation; Starting Cold Engine - Echo PB-413H Operator's Manual

Echo power blower operator's manual
Hide thumbs Also See for PB-413H:
Table of Contents

Advertisement

O
PERATION
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
• (PB-413H): Rotate spring loaded throttle arm downward to a comfort-
able operating position.

STARTING COLD ENGINE

PB-413H
1. Throttle Lever
Move throttle lever (A) to IDLE DETENT position.
PB-413T
1. Throttle Lever/Stop Switch
Move throttle lever (A) forward to idle position. Slide stop switch
(B) forward to run position.
PB-413H, PB-413T
2. Choke
Move choke (C) up to Cold Start position (
3. Primer
Pump primer bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4. Recoil Starter
Pull recoil starter handle (E) until engine fires (5 pulls maximum).
5. Choke
Move choke (C) down to run position (
restart engine.
NOTE
If engine does not start after 5 pulls, move choke to "Cold Start"
position, and repeat steps 4 & 5.
NOTE
Allow engine to warm up before use.
O
PB-413H
PB-413T
).
), and if necessary,
P
B
OWER
LOWER
'
M
PERATOR
S
ANUAL
A
B
A
C
D
15
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pb-413tPb-413h - 01-03Pb-413t - 01-03

Table of Contents