Electrical Preparation - Bosch SHV68E13UC - Accepts Custom Panels Integra 800 Installation Instructions Manual

Installation instructions
Hide thumbs Also See for SHV68E13UC - Accepts Custom Panels Integra 800:
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL
PREPARATION
Avoid Electrical
Shock Hazard
Do not work on an energized
circuit.
Doing
so
could
result
in serious
injury
or death.
Only
qualified
electricians
should
perform
electrical
work. Do not attempt any work on the dishwasher
electric
supply
circuit
until you are certain
the
circuit
is de=energized.
Avoid Fire Hazard
Make sure electrical
work is properly installed.
Only qualified
electricians should perform
electrical work.
Electrical
Supply
The customer has the responsibility
of ensuring that the
dishwasher
electrical installation
is in compliance with all
national
and local electrical
codes and ordinances.
The
dishwasher
is designed for an electrical
supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly
grounded electrical circuit with a fuse or breaker rated for 15
amps. Electrical supply conductors shall be a minimum #14
AWG copper wire rated at 75°C (167°F) or higher.
Avoid Fire Hazard
Make sure there are no loose electrical connections.
Make sure all electrical
connections
are properly
made.
Electrical
Connection
The dishwasher electrical supply junction box and dedicated
receptacle
must be mounted
in an accessible
cabinet
adjacent to the dishwasher (do not mount the junction box
or receptacle behind the dishwasher). You will need a
41/4 '' x 2" (108 x 51mm) opening throught the cabinet in
order to pass the junction box through (see Figure 4). If the
opening is made through wood, sand it smooth. If the opening
is made through metal, use the included protective grommet
or other approved method to protect wiring from damage.
Use the four screws included (or appropriate fastener) in the
parts bag to securely mount the junction box so that it can
be easily accessed (see Figure 4). The electrical supply can
be connected in two ways:
::'Pla'c'°e'
1
Id Wiring
Bectdcal Supply} /
/
L
Figure 4
junction
box and I
three prong plug I
are included
1
with dishwasher.//
Figure 5
Grounding
Instructions
The dishwasher
must
be properly
grounded
before
operating.
This
appliance
must
be connected
to
a grounded
metal
permanent
wiring
system,
or an
equipment grounding conductor must be run with the circuit
conductors
and connected
to the equipment
grounding
terminal or lead on the dishwasher.
Make sure that the
dishwasher is connected to a suitable ground in compliance
with all local codes or, in the absence of a local code, with
the NATIONAL ELECTRICAL CODE in the United States or
the CANADIAN
ELECTRIC CODE C22.1-1atest edition in
Canada as well as any provincial/state or municipal or local
codes that apply.
Dishwasher
Electrical
Rating
Volts
Hertz
Amperes
Watts
120
60
12
1,300
(max)
Method A - Three prong plug and receptacle
Use the included
three-prong
plug and junction
box to
connect to a dedicated household
receptacle. Make sure
the household
receptacle
meets the electrical
supply
requirements as well as national and local codes.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shv68e13uc 800She55p06uc/53Shv68e13uc/18Shv68p03uc/53

Table of Contents