Gas water heater power vented gas models with hot surface ignition
Table of Contents

Advertisement

4.
Make sure that the plastic tubing is still attached from the air pressure
switch to the port on the blower housing. Make sure the plastic tubing
is not folded anywhere
between the pressure switch and the blower
housing.
Make sure the ON/OFF switch is in the OFF position and that the outer
harness is connected from the blower control box to the connector
on the bottom side of the gas valve.
If the outer harness is not factory installed, make sure the ON/OFF
switch is in the OFF position and then connect the harness from the
blower control box to the connector on the bottom side of the gas
valve.
Before servicing the water heater, make sure the blower
assembly is unplugged or the electrical supply to the
water heater is tumed "OFF".
Label all wires prior to disconnection when servicing
controls.Wiring errorcan cause improperand dangerous
operation.Verify proper operation after servicing.
Failure to do this could result in death, serious bedil
injury,or propertydamage.
7.
a.)
b.)
c.)
d.)
e.)
f.)
Do not plug in power cord until vent system is completely installed.
This power vent heater operates
on 110-120 Vac, therefore
a
grounded outlet must be within reach of the six (6) foot (1.8 m) flexible
power cord supplied with the unit (see Figure 1). The power cord
supplied may be used only where local codes permit. If local codes
do not permit the use of a flexible power supply cord:
Make sure the unit is unplugged from wall outlet. Remove screws
and open panel on front of control box.
Cut the flexible power cord, leaving enough to be able to make
connections
and remove the strain relief fitting from box.
Install suitable conduit fitting in side of enclosure and then follow (d.)
and (e.) below.
Splice field wiring into existing wiring using code authorized method
(wire nuts, etc.).
Be certain that neutral and live connections
are not reversed when
making these connections.
Close panel on the side of control box, make sure that access panel
is secured shut.
H
i
ONiOFF
sw_
BLOWER
VACUUM
JUNCTION
SWITCH
BOX
(EXHAUST
STUD
BLOCKAGE)
HIGH
AIR
BLOWER
_
(_
_
TEMPERATURE
MOTOR
WATE_-----
_ _
I
HEATER
_
CONTROL
:_2_J"
6 PiN
_;_
CONNECTOR
_PZJ'
F
4 PIN
/
FV SENSOR
CONNECTOR
/
GND
FLAME
SENSE ROD
BLOWER ASSEMBLY
MOUNTING SCREW
(JACKET/TANK GROUND
CONNECTION)
HIGH AIR
I
I
I
SWITCH
G
X6WIRE
CABLE ASSEMBLY
You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric
utility requirements
when you install this wiring.
This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the
National Electrical Code NFPA 70 (current edition).
Note: If any of the original wire as supplied with the appliance must be replaced, it must be replaced
with
105°C wire or its equivalent.
17