Information Codes - Samsung DV455EVGSWR/AA User Manual

Gas and electric dryer
Hide thumbs Also See for DV455EVGSWR/AA:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

INFORMATION CODES

Information codes may be displayed to help you better understand what is occurring with your Dryer.
ERROR DISPLAY
tE
tE3
HE
dE
bE2
FE
2E
AE
Et
AE4
AE3
AE5
dF
For any codes not listed above, call 1-800-SAMSUNG (726-7864)
68_ Troubleshooting
DV455-02836F-02_EN_20120625.indd Sec6:68
DV455-02836F-02_EN_20120625.indd Sec6:68
MEANING
The thermistor resistance is very
low or high.
The resistance of the thermistor
for the vent blockage detection is
very low or very high.
Invalid heating Temp when the
dryer is running.
Running the dryer with door open
Invalid state of key. Circuit short
for 30 secs.
Invalid power source frequency
Electronic Control Problem
(Over Voltage Error)
Electronic Control Problem
(Communication Error)
Invalid state of Eeprom
communication
A communication error between
the Wi-Fi PBA and the MAIN PBA
A A communication error between
the DR Modem and the MAIN
PBA
A A communication error between
the LCD PBA and the MAIN PBA
Invalid door state for more than
256 milliseconds.
SOLUTION
Clean the screen or vent.
If the problem continues, call for service.
Clean the screen or vent
If the problem continues, call for service.
Call for service.
Clean the door and then restart.
If the problem continues, call for service.
Make sure a button is NOT being pressed
continuously. Try restarting the cycle.
If the problem continue, call for service.
Try restarting the cycle.
If the problem continues, call for service.
Call for service.
Call for service.
Call for service.
Call customer service.
Call customer service.
Call customer service.
Call for service.
2012-06-25