Step 1: Removing the module
Note:
Before removing the SCSI I/O module, label all cables. This
ensures their reconnection in the correct configuration.
1. Disconnect all SCSI cables from the SCSI I/O module.
2. Lift the port-colored SCSI I/O module latch 1 and pull the
SCSI I/O module out of the enclosure 2.
Figure 2: Removing the SCSI I/O module
Step 2: Installing the module
To install a SCSI I/O module:
1. Slide the SCSI I/O module into the bay until it clicks into
place.
Figure 3: Installing the SCSI I/O module
2. Reconnect all SCSI cables.
Note:
Make sure that all of the SCSI connectors are fastened tightly.
Verifying the replacement
After replacing the failed SCSI I/O module, verify that:
No error messages are displayed on the controller LCD.
The status LED is solid green.Returning the failed
component.
2
1
Returning the failed component
Please follow the return instructions provided in the
replacement component package.
Additional information
For additional information, refer to the MSA technical
documents web site at http://www.hp.com/go/msa1500cs.