WARNING!
It is extremely important that the power not be turned off during a firmware upgrade, as this could
cause device failure. If one is not already in place, consider adding a UPS to the system prior to
performing a firmware upgrade.
TIP:
Upgrading the firmware may take 5-10 minutes per device being upgraded.
NOTE:
You must do a system shutdown, followed by a cold boot, after this utility finishes in order for the
firmware upgrade to properly complete.
fio-update-iodrive [-f, -l, -p, -s, -h, -v] <fff file>
Filename (with full path) of the firmware file. Under Linux, this is typically in the
/usr/share/fusionio/images/ directory. On Windows, it can usually be found in
<fff file>
C:\Program Files\HP StorageWorks IO Accelerator\Firmware\.
-f
Force upgrade (used primarily to downgrade to an earlier firmware version)
CAUTION:
Use the -f option with care, as it could damage your board.
-p
Pretend: show what updates would be done (the firmware is not modified)
-l
List firmware available in the archive
Update devices in selected slots, using '*' as a wildcard for boards. The slots are in the
-s
following format: [[[[<domain>]:]<bus>]:][<slot>][.[<func>]]
CAUTION:
Use the -s option with care; updating a device in the wrong slot could damage it.