7. Secure the rails to the rack by inserting screws in the top and bottom holes on the left and
right sides on the front of the rack (as shown in the following figure). Do not insert screws into
the second-from-the-bottom hole at this time.
8. Insert screws into the middle two rear rail holes.
9. Verify that the rails are installed securely in the rack.
10. Carefully slide the array onto the rails, pushing it back until the flanges on the front of the
chassis meet the vertical supports.
11. Locate the second-from-the-bottom hole on the front right side of the rack. This hole should
be aligned with a hole in the flange or "ear" on the right front of the array. Place a screw in
the hole in the array, then insert a screwdriver through the hole in the front flange of the
array and tighten the screw to secure the array to the vertical supports, as shown in the
following figure. Repeat this step using another screw and the second-from-the-bottom hole
on the left side of the rack.
DSN-5000 series Hardware Reference Guide
Figure B-3. Securing the Rails to the Rack
Figure B-4. Sliding the Array onto the Rails
43