Wiring Diagrams; Standard Control Box - Chamberlain LA500 Installation Manual

Elite series vehicular swing gate operator
Hide thumbs Also See for LA500:
Table of Contents

Advertisement

WIRING DIAGRAMS

To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE
installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and
rating.
OPEN
CLOSE
STOP
C
N
COM
O
N
C
N
COM
O
N
Field Wiring
Edge
Edge
BOARD
EXP
+
C
N
COM
O
N
+
+
+
SW
ON
J5
POWER
ACCESSORY
Connection
42

STANDARD CONTROL BOX

Field Wiring
Wh te
White
Purple
Black
Red
Black
Power
Input
Red
Connection
Power
Input