2. Remove t he 3 loose nuts(afteryouremoved t he
rubber band) ontheterminal b lockusing 3/8" nut
driveror socket.
3.
Connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black wires
connected to the left terminal).
4. Replace the 3 nuts on the terminal block (see
figure 3).
5. Lower the terminal cover and replace the 3 screws.
Silver colored Terminal
Terminal
Block
Black
wire
Four
Conductor
Wire
Connection
to Range
(mobile
homes)
1. Remove the 3 screws at the lower end of the rear wire
cover, then raise the lower end of the rear wire cover
(access cover) upward to expose range terminal
connection
block (see figure 2).
2. Remove the three loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see figure 4).
7. Lower the terminal cover and replace the 3 screws.
Block
Silver Colored
Terminal
1-1/8" Dia.
A strainreJief
Direct
supplied by the user
Connection
must be installed at
240 V
Hole. Punch
this location
receptade
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Figure
3
1-1/8"
Dia.
Direct
Connection
Hole. Punch
out knockout
for !-3/8"
Dia.
Cord Kit Hole
A user
supplied
strain-relief
must be installed
V receptacle
at this location
I_J_t
NOTE; Be sure to remove
the supplie
grounding
strap
Figure 4