INSTALLATION
AND SERVICE
MUST BE PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location--Check
location where the range will be installed. Check for proper electrical supply, and the stability of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid
and level.
RANGE
OVERALL
DIMENSIONS
25- 3/4"
.........
_- 30"--.j._...
4
/2"
"5/8"w*
29-7/8"-'_
_5
Door Open
\41""
--
- -
_
_rW
Fig.
1
Depthis 28-I 3/32"with door handle.
RANGEELECTRICAL
CONNECTIONS
electricailoutletIocat,o_
Edge
2-5/8"for models equipped
withwarmer drawers,
3-1/2"for models equipped
withstorage drawers
Fig.
2
FRONT-- TYPICALCABINETINSTALLATION
SIDE
VIEW
Minimumto
1"4_
wall on either
side of range
above 36" height.
Fig. :3
_-
30"--_
30"
Minimum
_
1[_
_
_'t Minimumto
18" cabinetson
®'®
®'®
/
eitherside
of range.
,t_
30"
-_
1_-13"-_
Maximumdepth
for cabinets
[_
above rangetop.
i_
i iii
0" clearancebelow cookingtop and at rear of range.
*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACEAND
THE BOTTOM OF AN UNPROTECTED WOOD OR METAL
CABI NET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" FLAME RETARDANT
MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEETSTEEL, 0.015" STAINLESS STEEL, 0.024"ALUMINUM
OR 0.020" COPPER.
0" CLEARANCE
IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION
REQUIREMENTS
PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BU RNS OR FIRE BY REACHING OVER HEATED SU RFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY
A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
IMPORTANT
SAFETY
INSTRUCTIONS
• ALL RANGES
CAN TIP
• INJURYTO
PERSONS
COULD
RESULT
• INSTALL
ANTI-TIP
DEVICE
PACKED
WITH
RANGE
• SEE INSTALLATION
INSTRUCTIONS
_!VAt/-'l=l_ll_[_ll If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death.
Important
Notes to the Installer
Read all instructions contained in these installation instructions
before installing range.
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your owner'sguide for future reference.
As when using any appliance generating
heat, there are
certain safety precautions you should follow. These are listed
in the Use & Care Guide, read it carefully.
Be sure your range is installed and grounded properly by a
qualified installer or service technician.
Make sure the wall coverings around the range can withstand
the heat generated by the range.
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be avoided.
Serial Plate Locations:
Serial
plate location:
Serial plate is located on the lower right front frame of the appliance.
Alternate location may be under cooktop.
316454912
EspaSol - Paginas 5-8
Need help?
Do you have a question about the 9743 - 30 in. Electric Range and is the answer not in the manual?
Questions and answers