ELECTRONIC SURFACE ELEMENT CONTROL SYSTEM (ESEC 30) ERROR CODE DESCRIPTIONS
When a specific error condition occurs in the ESEC system, the control will beep and usually display an error code. These error codes will
appear in the two front element displays with "E" in the left display and the code number in the right display. For each Error Code or symptom
there is a listing of the likely cause or failure condition, as well as suggested corrective actions to be taken. Always reset the power by disconnecting or turning
off the power supply for 30 seconds to see if the failure condition will clear. If the error code returns perform the steps one at a time in the order listed below to
correct the specific failure condition. NOTE: If multiple changing error codes are displayed check for disconnected wires or cables.
Tech Sheet Abbreviations and Terminology
EOC = Electronic Oven Control
ESEC = Electronic Surface Element Control
UIB = User Interface Board
TSEC = Touch Sensor Electronic Control
VSC = Variable Speed Control
PS
= Power Supply board (PS1 , PS2, etc.)
Error Code/
Likely Cause or Failure Condition
Suggested Corrective Action
Symptom
ESEC key display ribbon cable is
1. Check/reseat ribbon connection J3 on the ESEC 30 UIB to J5 on TST panel.
Control
disconnected or defective
2. Test continuity of ribbon harness. Replace if defective.
Beeping
3. Replace UIB.
No Error
4. Replace TST panel.
Codes
1. Check/reseat ribbon connection J2 on the ESEC30 UIB to J4 on TST panel.
ESEC key display ribbon cable is
"E " Only
2. Test continuity of ribbon harness. Replace if defective.
disconnected or defective.
3. Replace UIB.
4. Replace TST panel.
1. Reset power supply to range to see if failure code will clear.
11
2 Check/reseat ribbon harness and connectors between the TST panel and ESEC 30 UIB. Replace if defective.
Shorted keypad.
3. Replace the TST panel.
4. Replace the UIB.
1. Check/reseat ribbon connection J4 on the ESEC 30 UIB to J3 on TST panel.
ESEC key read ribbon cable is
2. Test continuity of ribbon harness. Replace if defective.
14
disconnected or defective.
3. Replace UIB.
4. Replace TST panel.
21
Communication failure between the
1. Test the harness between UIB connector P8 and filter board connector X14.
filter board and UIB
2. Replace the UIB.
3. Replace the filter board.
30 or 70
AC Input voltage too high
1. Verify chassis ground wire connection to terminal X17 on filter board & to chassis ground.
35 or 75
AC Input voltage too high
2. Test for approximately 240 volts AC at filter board terminals X1 - X4 & X2 - X5.
3. If voltage is correct (240 volts AC ± 10%) replace filter board.
31
Synchronization failure - left side
1. Verify all cable and harness connections to the left side cooking zones generator board.
cooking zones generator board
2. Replace the generator board.
32 or 33
Power supply defect - left side
1. Test all cables & connections on filter board.
cooking zones
2. Replace the filter board.
3. Replace the generator board for the left side cooking zones.
34
Internal communication failure -
1. Check cable between filter board X12 connector and X10 connector on left side cooking zones.
generator board, left side cooking zones
2. Replace left side cooking zones generator board.
3. Replace filter board.
36
Communication error
1. Test / reseat communication harness between UIB connector P8 and filter board X14 connector.
(left cooking zones)
Replace if defective.
2. Test / reseat communication harness between filter board connector X12 & left side cooking zones
generator board connector X10. Replace if defective.
3. Replace filter board.
4. Replace left side cooking zones generator board.
5. Replace UIB.
37
Heat sink temp sensor break
1. Replace left side cooking zones generator board.
(left cooking zones)
39
Configuration mismatch between
1. Make sure the UIB is connected correctly.
the UIB and the filter board. (Can
2. Press and hold both the right front and right rear ON/OFF keys until the ESEC displays change
occur when a filter board is replaced).
to "88". Then press and hold the left front and left rear ON/OFF keys until the beep sounds and
the configuration starts. The display segments will scroll top to bottom until the configuration is
complete.
3. Replace filter board.
Surface unit temp sensor break
1. Verify surface unit temperature sensor is correctly connected to the appropriate generator board
51
Left front
connector (refer to wiring diagram).
52
Left rear
2. Replace surface unit if temperature sensor resistor value is not approximately 1000 ohms (blue wires)
54
Right rear
at room temperature.
55
Right front
3. Replace associated generator board.
Surface unit sensor too hot
1. Verify cooktop ventilation is correct (airway & fans).
61
Left front
2. Verify integrity of the white insulation material on induction element.
62
Left rear
3. Verify surface unit temperature sensor is correctly connected to the appropriate generator board
64
Right rear
connector (refer to wiring diagram).
65
Right front
4. Replace surface unit if temperature sensor resistor value is not approximately 1000 ohms
(blue wires) at room temperature.
5. Replace associated generator board.
TST = Touch Sensor Technology (touch control glass panel)
RTD = Resistance Temperature Device. (Temp Probe or Temp Sensor)
TCO = Thermal Cut Out also "Thermo Disc" or "Thermal Limiter"
Error
Likely Cause or Failure Condition
Suggested Corrective Action
Code
71
Synchronization failure - Right side
1. Verify all cable and harness connections to the right side cooking zones Generator Board.
cooking zones generator board
2. Replace the generator board.
72 or 73
Power supply defect - right side
1. Test all cables & connections on filter board.
cooking zones
2. Replace the filter board.
3. Replace the generator board for the right side cooking zones.
74
Internal communication failure -
1. Check cable between the filter board X12 connector and the X10 connector on right side cooking
generator board, right side
zones generator board.
cooking zones
2. Replace right side cooking zones generator board.
3. Replace filter board.
76
Communication error
1. Test / reseat communication harness between UIB connector P8 and filter board X14 connector.
(right cooking zones)
Replace if defective.
2. Test / reseat communication harness between filter board connector X12 & right side cooking zones
generator board connector X10. Replace if defective.
3. Replace filter board.
4. Replace right side cooking zones generator board.
5. Replace UIB.
77
Heat sink temp sensor break
1. Replace right side cooking zones generator board.
(right cooking zones)
ADDITIONAL FAILURE CONDITIONS
Symptom or Failure
Control Display
Possible Cause or Condition
Pan does not heat up.
Pan too small for proper pan detection
Normal operation
and only works with low power.
Flashing power level
Pan not detected.
Display and pan does not
heat.
Induction surface unit not correctly
connected or surface unit open.
Distance between surface unit and
glass ceramic too large.
Individual buttons
None
1. Test cables & connections.
cannot be used or
2. Touch control defective.
cannot always be used.
3. UIB defective.
Cooking power too low
None
Fluids spilled or object lying on
or shuts down
control panel keypads.
prematurely.
Normal operation
Ventilation slots obstructed.
Unsuitable pots (bottom bent).
Distance between surface unit and
glass ceramic too large.
Fan does not start.
Steady "HE" in display
Temperature sensor defect.
"HE"
when cooking zone is
cold and switched off.
UIB not powered
Cooktop does not
Blank
initialize/operate.
No display
Defective UIB power supply (PS1).
No beep
Defective UIB.
Suggested Corrective Action
Use larger pan or this pan on a smaller cooking zone. Refer to
owners guide for proper pan selection.
Check whether the pots or pans are suitable for induction.
Refer to owners guide for proper pan selection.
Check the surface unit wire terminal connections. Ensure that
they are properly connected and tightened. Test continuity of
element (should be less than 1 ohm).
Check whether the surface unit is properly positioned and
touching the glass cooktop surface.
1. Follow instructions for proper use of touch controls.
2. Verify harness going between UIB ribbon connectors and
touch panel connectors. Replace if defective or damaged.
3. Verify there is no mechanical interference close to the
touch panel (wires, utensils, etc.).
4. Replace touch panel.
5. Replace UIB.
Clean up spills or remove objects. Restart cooktop in normal
manner.
Clear vent openings.
.
Follow owner's guide for proper pan selection
Check whether the surface unit is properly positioned and
touching the glass cooktop surface.
1. With two surface units operating, verify that the fans
run at a slow speed. If fans do not run, check for
foreign objects or stuck fan motor.
2. Test continuity of motor windings. Replace motor if open.
3. Replace filter board.
1. Test surface unit RTD approx. 1K ohms at room temperature.
Replace surface unit if resistance is not correct.
2. Replace generator board.
Verify installation and harness connections to UIB
1. Check for 120 volts AC at the power supply board connector
P1 between pins 1 and 4. Test harness if voltage is not present.
2. Test for 8 volts DC output at the power supply board connector
P3 between Pins 1 and 2. Replace power supply board if
voltage is not correct.
3. Test for 16 volts DC at output at power supply board connector
P3 between Pins 1 and 3. Replace power supply board if voltage
is not correct.
Replace UIB.