(*)Parameter2
Parameter 2 shows whether the lamp replacement time is close or not, based on the
following calculation:
(Lamp service life-100 hours )≦ Lamp operating time < Lamp service life
Lamp replacement time not close
Lamp replacement time close
Lamp life exceeded
# Communication Examples
◇ When requesting the current lamp operating time (if the lamp operating time is 150 hours)
CTLR
'?'
DLA
'1'
SP
'U1C'
CR
Character
'@'
'1'
SP
'0'
39
'0'
'1'
'2'
SP
'08CA'
SP
'0'
HEX
30H
31H
32H
CR