Outline; Communication Format; Data Format - JVC DLA-DS1U - General Purpose D-ila Projector Manual

Rs-232c control specifications
Table of Contents

Advertisement

1.OUTLINE
1.
1.
1.
This document describes the communication and data formats used to control the projector via
its RS-232C port.
2. COMMUNICATION FORMAT
2.
2.
2.
Transfer Rate :
Data Length :
Parity Bit
Start Bit
Flow Control :
3.DATA FORMAT
3.
3.
3.
3.1
Command Data Format (External Control to Projector)
Header
ID
SP
Header
: Indicates the beginning of data and data type
ID
: Identification number of Projector
SP
: Indicates the separation between ID and command, command and parameter,
CR
: Indicates the end of data(0DH)
3.2
Tally (Response) Data Format (Projector to External Control)
3.2.1
Tally (Response) Data when Terminated Normally
Header
ID
Header
ID
SP
Normal Termination : '0'(30H)
Status
CR
* Parameter is sent when tally (response) data is issued in response to a query (request for data.)
9600, 19200(default) bps
8 bits
:
None
:
1 bit
None
Command
SP
Parameter
'!'(21H)
Command for the Projector
'?'(3FH)
Query to the Projector (Request for data)
parameter and parameter(20H)
SP
Normal Termination Status
:
Indicates the beginning of tally (response) data
'@'(40H)
: Identification number of the Projector
: Indicates the separation between ID and status, status and parameter,
parameter and parameter(20H)
: Indicates the end of data(0DH)
SP
Parameter
SP
Parameter
2
SP
・・
CR
SP
Parameter
・・
CR
There is