Haier GDZ10-0677 User Manual page 8

Automatic electric dryer
Table of Contents

Advertisement

English
maintain a minimum of 12 inches (30.5cm) clearance between the vent hood
and the ground or any other obstruction. The vent flap should be able to move
freely, although vertical orientation of the exhaust system is acceptable. Certain
extenuating circumstances could affect the performance of the dryer:
1. Only rigid metal duct work should be used.
2. Venting vertically through a roof may expose the exhaust system to down
drafts causing an increase in vent restriction.
3. Running the exhaust system through an uninsulated area may cause
condensation and faster accumulation of lint.
4. Compression of crimping of the exhaust system will cause an increase in
vent restriction.
5.
The exhaust duct shall be 4 inch (102 mm) in diameter.
The exhaust system should be inspected and cleaned a minimum of every 12
months with normal usage. The more the dryer is used the more often you
should check the exhaust system and vent hood for proper operation.
No. of 90º
elbows
0
1
2
3
7
RECOMMENDED MAXIMUM
Recommended
Rigid Metal
Flexible Metal
Flexible metal
90 ft.
metal shoud only
60 ft.
be used between
the dryer and the
45 ft.
wall.Maximum
length to be 7.5ft.
35 ft.
Exhaust Hood Types
Use only for short
Rigid Metal
60 ft.
45 ft.
35 ft.
25 ft.
run installations
Flexible
Metal
Flexible metal
metal shoud only
be used between
the dryer and the
wall.Maximum
length to be 7.5ft.