10-2 Precautions in Operation
General information
Refer to chapter 17: The troubleshooting and inspection of alternator
Refer to chapter 17: The service procedures and precaution items of starter motor
Specification
ID of starting clutch gear
OD of starting clutch gear
Torque value
Flywheel nut
Starting clutch hexagon bolt
8 mm bolts
12 mm bolts
Tools
Special tools
A.C.G. flywheel puller: SYM-3110A00
Universal holder: SYM-2210100
Item
Standard value (mm)
25.026~25.045
42.175~42.200
5.0~6.0kgf-m
1.0~1.4kgf-m with adhesive
0.8~1.2kgf-m
1.0~1.4kgf-m
85
Limit (mm)
25.100
42.100