IBM 8669 - Eserver xSeries 342 Hardware Maintenance Manual page 94

Hardware maintenance manual
Table of Contents

Advertisement

Beep/Symptom
2-2-2 (Keyboard controller failed)
2-2-3 (CMOS power failure and
checksum checks failed)
2-2-4 (CMOS configuration
information validation failed)
2-3-1 (Screen initialization failed)
2-3-2 (Screen memory failed)
2-3-3 (Screen retrace failed)
2-3-4 (Search for video ROM failed)
2-4-1 (Video failed; screen believed
operable)
3-1-1 (Timer tick interrupt failed)
3-1-2 (Interval timer channel 2 failed) 1. System Board
3-1-3 (RAM test failed above
address OFFFFH))
3-1-4 (Time-Of-Day clock failed)
3-2-1 (Serial port failed)
3-2-2 (Parallel port failed)
3-2-4 (Failure comparing CMOS
memory size against actual)
3-3-1 (Memory size mismatch
occurred; see "Memory Settings" on
page 25)
3-3-2 (Critical SMBUS error
occurred)
3-3-3 (No operational memory in
system)
4-4-4 (Optional system management
adapter not installed in slot 1 or not
functioning correctly)
84
Hardware Maintenance Manual: xSeries 342 Type 8669
FRU/Action
1. System Board
2. Keyboard
1. Battery
2. System Board
1. Battery
2. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. DIMM
2. System Board
1. Battery
2. System Board
1. System Board
1. System Board
1. DIMM
2. Battery
1. DIMM
2. Battery
1. Disconnect the server power cord from outlet, wait 30 seconds and
retry.
2. System Board
3. DIMMs
4. DASD Backplane
5. Power Supply
6. Power Supply Backplane
7. 12C Cable
1. Install or reseat the memory modules, then do a 3 boot reset. (See
"Using the Configuration/Setup Utility program" on page 23.)
2. DIMMs
3. Memory Board
4. System Board
1. Verify that adapter is installed in slot 1.
2. Adapter
3. System Board

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 342 type 8669