External Control

7 About the external control

This monitor has two external control terminals.
• MAKE/TRIGGER terminal (RJ-45): The following external control systems are available.
(1) MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to
the GND pin terminal, or disconnecting (opening) it (☞ below).
(2) TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the
corresponding pin terminal (☞ below).
• RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-232C system. (☞ page 17)
• Control priority is as follows.
MAKE > TRIGGER, RS-232C, buttons and menu on the monitor
• You can use the external control even when "CONTROL LOCK" is set to "ON" (☞ page 15).
• When the monitor is off (on standby), external control is not available.

7 Using the MAKE/TRIGGER system

You can control the monitor by a personal computer or dedicated controller*
*
1
The controller is not commercially available. Consult your dealer if you need it.
The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in
"REMOTE SETTING" (☞ "PIN1, PIN2, PIN3, PIN4, PIN5" on page 15).
Pin No.
This is a female
1
terminal.
2
3
4
*
2
The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal is
invalid.)
3
*
The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE system.
• You cannot change the functions assigned to the pin terminals from 6th to 8th.
• When "FORMAT INDICATOR" in "FUNCTION SETTING" is set to "ON," the TALLY lamp cannot be controlled
by the external control (☞ page 14)
• You cannot assign the same function to different pin terminals.
• The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and
opening it.
To assign the functions to the pin terminals
For the operation procedure, see page 7.
1
Select "REMOTE SETTING" on the SET-UP MENU.
2
Set "TYPE SEL." to "SET."
3
Select a pin name ("PIN1" – "PIN5") for which you want to assign a function, then select the function you want
to assign.
• For selectable functions, see the table on the right.
1
.
Pin name
Pin No.
Pin name
PIN1
5
PIN5
PIN2
6
PIN6 (TALLY)*
2
PIN3
7
PIN7 (ENABLE)*
3
PIN4
8
PIN8 (GND)
Functions controlled by the MAKE/TRIGGER system
Display
Functions to be controlled
TALLY SEL
Selects the color of the tally lamp.
SDI 1
Changes the input to "SDI 1."
SDI 2
Changes the input to "SDI 2."
VIDEO/COMPO. Changes the input to "VIDEO/COMPO."
MARKER
The area marker and the safety marker indication
FRAME
Indication of the area of the specified aspect ratio
C.MARKER
The center marker indication
MARK.SEL
Selects the items of "MARKER"*
ASPECT
Changes the aspect ratio.
STATUS
Status display*
5
L.METER
Audio level meter display
TIME CODE
Time code display
☞ "SOURCE ID" on page 15
SOURCE ID
WAVE FORM
Wave form monitor display*
7
C. C.
Closed caption display
COLOR OFF
Color off
SCR CHECK
Screens check
DYNAMIC
Adjusts the picture to be suitable for a bright place.
FOCUS ASSIST Helps to focus the picture.
COLOR RANGE Reduces the difference of the luminance level specific to
the LCD panel.
MUTING
Muting on/off
— — —
No function
*
4
Selects which functions in "MARKER" are activated, non-"R-" items or "R-" items (☞ page 11).
*
5
Displays the information shown when the button of the current input is pressed (☞ "On the Status Display" on page 7).
While controlling with the MAKE system, the information is displayed only at the moment of short-circuiting.
*
6
While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and hidden
(opening). When "LEVEL METER ch" is set to "OFF," the level meter is not displayed ("NO EFFECT" appears). While
controlling with the TRIGGER system, the number of the audio channels displayed is changed (between OFF, 12CH
and 8CH).
*
7
While controlling with the MAKE system, the wave form monitor will not disappear until opening the terminal even when
"AUTO OFF" is set to "ON."
8
*
For analog composite signals (NTSC and B/W60 only). While controlling with the MAKE system, the closed caption
is switched between displayed (short-circuiting) and hidden (opening). When "CLOSED CAPTION" is set to "OFF," the
closed caption is not displayed ("NO EFFECT" appears). While controlling with the TRIGGER system, the type of the
closed caption can be selected.
*
9
While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen
(short-circuiting). While controlling with the TRIGGER system, the screen changes as follows:
Normal screen
Red screen
Blue screen
Green screen
Opening
Green
Invalid
Invalid
Invalid
Off
Off
Off
4
Non-"R-" items
4:3
☞ "On the Status Display" on page 7
*
Off
Off
Off
*
Color
*
Off
Off
Off
Off
16
Short-circuiting
Red
Valid
Valid
Valid
On
On
On
"R-" items
16:9
6
On
On
On
8
Monochrome
9
On
On
On
On